USER'S
MANUAL
F
FA
A
A1
1
14
4
45
5
5C
C
C S
S
Se
e
ec
c
cu
u
urrrriiiitttty
y
y S
Sy
ys
s
stttte
em
m
First Alert
N8600 2/97
Page 1: ...USER S MANUAL F F F FA A A A1 1 1 14 4 4 45 5 5 5C C C C S S S Se e e ec c c cu u u ur r r ri i i it t t ty y y y S S S Sy y y ys s s st t t te e e em m m m First Alert N8600 2 97...
Page 2: ...C KEYS 22 OUTPUT RELAY OPTIONS 23 TESTING THE SYSTEM 24 PAGING FEATURE 25 TROUBLE CONDITIONS 26 CHECK and BATTERY Displays 26 Other Trouble Displays 27 Total Power Failure 28 CALLING FOR SERVICE 28 FI...
Page 3: ...are controlled by your keypad s which are described in the next section ABOUT THE KEYPADS Burglary Protection Zones The burglary protection portion of your system must be turned on or armed before it...
Page 4: ...ound at the Keypad s whenever a door or window is opened Phone Access Voice Response Capability Optional Your system may include a phone module that will permit you to access the system via a Touch to...
Page 5: ...es below The keys on some keypads are located behind a flip down cover which can be removed if desired Keypad Types There are two basic types of keypads Alpha and Fixed Word either of which may have b...
Page 6: ...ature is ON 00 ALARM CHECK FIRE AWAY STAY INSTANT BYPASS NO AC CHIME BAT NOT READY 00 00 STYLE A 00 ALARM FIRE AWAY BYPASS STAY CHECK INSTANT NO AC NOT READY CHIME BAT 00 STAY FIRE ALARM AWAY STYLE B...
Page 7: ...5 6 7 8 9 0 ARMED ALARM CHECK FIRE AWAY STAY INSTANT BYPASS NO AC CHIME BAT NOT READY ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME READY 1 A B C D 2 3 4 5 6 7 8 9 0 F...
Page 8: ...entry exit door will cause an instant alarm 9 CODE KEY Used to assign additional security codes for other users of the system 10 CHIME KEY Turns CHIME mode on and off When on the opening of windows or...
Page 9: ...ER REMOVED DISARMED READY TO ARM SHOWN WITH FLIP DOWN KEY COVER REMOVED TYPICAL ALPHA KEYPAD Fixed Word Keypads are functionally similar except for screen displays see page 6 IMPORTANT When entering c...
Page 10: ...tection zones The Master security code can be used to assign up to 6 secondary User codes up to 7 if no Duress code is assigned The Master code can also be used to change any User code or to remove d...
Page 11: ...t signifies that the code has been deleted To Change Your Master Code Enter the original Master code 8 2 New Master Code New Master Code again The keypad will beep 3 times indicating acceptance of the...
Page 12: ...y entrance where a longer delay may be required to walk to the keypad to disarm the system You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM arming modes These...
Page 13: ...the READY key do not enter code first Secure or bypass the zones displayed before arming the system A Ready message will be displayed when all protection zones have been either closed or bypassed and...
Page 14: ...he zone s to be bypassed e g 06 10 13 etc Single digit zone numbers must be preceded by a zero e g 05 06 3 When finished the keypad will momentarily display a Bypass message for each by passed zone nu...
Page 15: ...y leave certain windows open when arming at night To use this feature enter your security code press the BYPASS key then stop In a few moments all open zones will be displayed along with a Bypass mess...
Page 16: ...EXIT DOOR PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY Anyone entering later can enter through an entry exit door without causing an alarm but they must disarm the system within the entry delay...
Page 17: ...rotected perimeter door or window is opened but you may otherwise move freely throughout the premises An alarm sounds immediately if anyone opens an entry exit door If you wish to open the entry exit...
Page 18: ...ately if a protected window or non entry exit door is opened or if any movement is detected inside your premises You may re enter through an entry exit door but must disarm the system within the entry...
Page 19: ...isplays the armed MAXIMUM message The red ARMED indicator lights 3 You may leave through an entry exit door during the exit delay period without causing an alarm After the exit delay expires the syste...
Page 20: ...arm SEE IMPORTANT NOTE AT LEFT Enter your security code and press the OFF key to silence the alarm or warning tones of a Memory of Alarm Note the zone in alarm on the keypad display and make that zone...
Page 21: ...d or alarm sounder timeout occurs The keypad displays EXIT ALARM or EA as well as a zone indication An exit alarm message will be sent to the central station Note The latter EXIT ALARM conditions also...
Page 22: ...external sounders that may be connected ALARM plus a zone number is also displayed A personal emergency alarm sends an emergency message to the central station and sounds at keypad s but not at exter...
Page 23: ...AL FIRE 95 ___SILENT ___AUDIBLE ___PERSONAL ___FIRE ___REQUEST FOR SERVICE 07 3 ___SILENT ___AUDIBLE ___PERSONAL ___FIRE 96 NOTE KEYS A B C AND D ARE NOT PRESENT ON ALL KEYPADS IF THE D KEY IS NOT PRE...
Page 24: ...3 beeps The keypad will sound a single beep every 40 seconds as a reminder that the system is in the test mode If these sounds do not occur call for service immediately 4 Open and close each protecte...
Page 25: ...lways appear at the beginning of the display on your pager EEE will be a 3 digit number that describes the event that has occurred in your system see explanation below NNN will be a 3 digit User or zo...
Page 26: ...SERVICE IMMEDIATELY Determine if the zone s displayed are intact and make them so if they are not If the problem has been corrected the display can be cleared if you enter the OFF se quence security...
Page 27: ...re than one day with AC present CALL FOR SERVICE 3 LO BAT zone descriptor Indicates that a low battery condition exists in the wireless or BAT with zone No transmitter number displayed and accompanied...
Page 28: ...r Cd See page 23 for information on this feature This display occurs if the D key is pressed to request service Also displayed if key pair are pressed and programmed to send a request for service mess...
Page 29: ...d TYPICAL FIRE EMERGENCY DISPLAYS FIRE 05 MASTER BEDROOM 05 ALARM FIRE AC ALPHA FIXED WORD Silencing Fire Alarms 1 You can silence the alarm at any time by pressing the OFF key the security code is no...
Page 30: ...ly 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number s of the zone s in an alarm condition will be displayed at the Keypad Ask your installer which lettered key o...
Page 31: ...ned in the National Fire Protection Association s NFPA Standard 74 noted below Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of t...
Page 32: ...lan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes...
Page 33: ...ter disarming enter code again Press OFF key again Keypad will beep rapidly upon entry if alarm has occurred Alarm display will remain upon disarming until cleared Duress if active Arm or disarm norma...
Page 34: ...TROUBLE a LO BAT displayed with description of transmitter b LO BAT displayed with no transmitter description c CHECK displayed Descriptor of troubled protection zone is displayed TWO SHORT BEEPS Key...
Page 35: ...N BATT WEAK c TROUBLE a BAT displayed with ID number of transmitter b BAT displayed with no transmitter ID c CHECK displayed Troubled protection zone is displayed TWO SHORT BEEPS Keypad only ARM AWAY...
Page 36: ...nstaller see Page 22 Zone numbers 08 and 09 are reserved for Duress and Tamper signal reporting to the central station This chart may be used to record the specific zone number assignments for your sy...
Page 37: ...del FA145C Type of Alarm Burglary Fire Both Installed by ______________________________________ Serviced by ________________________________________ name name ______________________________________ __...
Page 38: ...and Vents G ADDITIONAL PERTINENT INFORMATION ____________________________________________________________________________________________________ _____________________________________________________...
Page 39: ...ette tiquette certifie que le mat riel est conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Le minist re n assure toutefois pas que le mat riel fo...
Page 40: ...and the radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user...
Page 41: ...tical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe necessary The telephone company may make...
Page 42: ...tector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may not...
Page 43: ...he environment usage and the specific wireless device being used External factors such as humidity high or low temperatures as well as large swings in temperature may all reduce the actual battery lif...
Page 44: ...L OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE...