background image

P/N:380745454 Rev:02

OWNER’S  MANUAL

Read all safety precautions and instructions carefully 
before operating equipment.
Ensure engine is stopped and level before performing 
any maintenance or service.

IMPORTANT: 

Record product information to reference when ordering parts or 
obtaining warranty coverage.

Serial Number:

PORTABLE  GENERATOR

MODEL

 

NUMBER

P08005

Rev Level:00

DO NOT RETURN TO 
          STORE!

CALL US FIRST!

CUSTOMER HOTLINE

1-844-347-6261

FOR QUESTIONS OR SERVICE 
           INFORMATION

Purchase Date:

Summary of Contents for P08005

Page 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number PORTABLE GENERATOR MODEL NUMB...

Page 2: ...lectric Start 19 Starting the Generator Remote Start 20 Connecting Electrical Loads 21 Stopping the Engine 21 Low Oil Shutdown 22 Do Not Overload Generator 22 Introduction Battery Cable Connection Con...

Page 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...ns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loos...

Page 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Page 8: ...form your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or...

Page 9: ...ng wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with th...

Page 10: ...nnection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Page 11: ...Flat Free Wheel 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel 13 Handle 14 Battery 15 Remote Holder English Customer Service 1 844 FIRMAN1 We are always working to improve our products Therefore...

Page 12: ...sed if your body becomes a path through which electricity travels to reach ground This could happen when you touch an appliance or cord that is live through faulty mechanism damp or worn insulation et...

Page 13: ...liance can cause a ground fault A GFCI receptacle is different from conventional receptacles In the event of a ground fault a GFCI will trip and quickly stop the flow of electricity to prevent serious...

Page 14: ...r light will flash once to program the remote START 6 Push and hold the program button approximately 3 seconds until the indicator light turn off The generator is now programmed to start remotely NOTE...

Page 15: ...hase Power Factor Voltage Regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricating Oi...

Page 16: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Page 17: ...ed fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engin...

Page 18: ...weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator C...

Page 19: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Page 20: ...ine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is felt and then pull r...

Page 21: ...ct all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the engine switch to the...

Page 22: ...CONVENIENCE ANDITISREADYTO STARTTHEGENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical...

Page 23: ...ill void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle...

Page 24: ...op the engine Check oil level with dipstick If oil level is between LOW and HIGH mark on dipstick 1 DO NOT try to restart the engine 2 Contact an Authorized FIRMAN Service Dealer 3 DO NOT operate engi...

Page 25: ...d replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better and last longer English Customer Service 1 844 FIRMAN1 ITEM NOTES Daily Bef...

Page 26: ...ry animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine c...

Page 27: ...ing CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks c...

Page 28: ...xterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to en...

Page 29: ...sential fuel system parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which le...

Page 30: ...s using a fuel stabilizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in...

Page 31: ...tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engine 11 Contact author...

Page 32: ...Page 30 PARTS DIAGRAM AND PART LIST P08005 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 137 138 139...

Page 33: ...Page 31 439cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 34: ...4 4 2 2 4 1 1 3 4 1 12 1 2 1 1 1 2 2 2 1 1 1 1 1 1 1 1 8 1 1 2 1 1 4 4 4 1 2 1 1 1 3 1 1 4 2 2 2 2 2 2 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 1...

Page 35: ...buretor Gskt carb Carburetor Choke Connector 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 10...

Page 36: ...by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a w...

Page 37: ...f God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts units used for prime power in place of existing utility power where u...

Page 38: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Page 39: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Page 40: ...P N 380745454 Rev 02 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...

Reviews: