!WARNING: 

T

HIS SMOKE ALARM WILL SOUND A SHORT BEEP WHEN POWER IS CONNECTED

.

D

O NOT USE THIS SMOKE ALARM WITH ANY EXTERNAL BUG SCREENS OR SMOKE ALARM

GUARDS

. U

SE OF THESE TYPES OF DEVICES MAY REDUCE SMOKE ALARM RESPONSE TIME

.

CONTENTS

p.1-2

IMPORTANT INFORMATION ABOUT YOUR SMOKE ALARM

p.2

WHAT SMOKE ALARMS CAN DO

p.2-3

WHAT SMOKE ALARMS WILL NOT DO

p.3-5

WHERE YOU SHOULD INSTALL YOUR SMOKE ALARMS

p.5

SPECIAL DIRECTIONS FOR INSTALLING YOUR SMOKE
ALARM IN MANUFACTURED AND MOBILE HOMES

p.5-6

WHERE YOU SHOULD NOT INSTALL SMOKE ALARMS

p.6

HOW TO INSTALL YOUR SMOKE ALARM

p.6-7

WEEKLY TESTING OF YOUR SMOKE ALARM

p.7

TAKING CARE OF YOUR SMOKE ALARM

p.7-8

REPLACING THE BATTERY

p.8

USING THE TAMPER RESIST LOCKING MECHANISM

p.9

SPECIAL SMOKE ALARM FEATURES

p.10

WARRANTY INFORMATION

p.10

WHERE TO SEND YOUR SMOKE ALARM FOR SERVICE

IMPORTANT INFORMATION ABOUT 

YOUR SMOKE ALARM

• Before installing your smoke alarm, you must read this entire

Owner’s Manual.

• This alarm incorporates the internationally recognized horn signal for

evacuation. During alarm mode, the horn produces three short beeps
followed by a 2 second pause and then repeats. This pattern is
somewhat different than the previous alarm sound, which continually
beeped.

• Install a smoke alarm in each room and area of your home. See

“WHERE YOU SHOULD INSTALL YOUR SMOKE ALARMS.”

1

Smoke Alarm 

®

©1998 Maple Chase Company

Battery

Operated

110-644

MODELS A, B, C,
E AND PB

PLEASE READ AND SAVE

THIS MANUAL

Installer: Please leave this 
manual with the product.

110-644  10/5/00  2:17 PM  Page 1

Summary of Contents for A

Page 1: ... 7 8 REPLACING THE BATTERY p 8 USING THE TAMPER RESIST LOCKING MECHANISM p 9 SPECIAL SMOKE ALARM FEATURES p 10 WARRANTY INFORMATION p 10 WHERE TO SEND YOUR SMOKE ALARM FOR SERVICE IMPORTANT INFORMATION ABOUT YOUR SMOKE ALARM Before installing your smoke alarm you must read this entire Owner s Manual This alarm incorporates the internationally recognized horn signal for evacuation During alarm mode...

Page 2: ... missing dead or put in wrong A SMOKE ALARM WILL NOT SENSE A FIRE WHEN THE SMOKE CANNOT REACH THE ALARM If a fire starts in a chimney wall roof the other side of a closed door or any other isolated area the smoke alarm may not sense the smoke and will not give a warning If you do not have an alarm in the bedroom and sleep with the door closed a fire inside the bedroom may not sound the alarm locat...

Page 3: ...uired within the family unit Section 2 1 1 1 reads as follows Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics The provisions of 2 1 1 1 represent the minimum number of detectors required by this standard It i...

Page 4: ...cks the path of the smoke to the alarm Do install a smoke alarm in a room where flammable household chemicals or solvents are stored For example if you keep kerosene paint thinner or certain types of contact cements within your resi dence install a smoke alarm in that room unless not recommended by a situation described in the section WHERE YOU SHOULD NOT INSTALL SMOKE ALARMS Do install smoke alar...

Page 5: ... you notice the outside walls or ceiling are unusually hot or cold put the smoke alarm on an inside wall WHERE YOU SHOULD NOT INSTALL SMOKE ALARMS Do not install a smoke alarm within close proximity of heating and cooling supply vents or within close proximity of return or fresh air vents Smoke may be blown away from the smoke alarm by the supply vents or could be diffused or reduced by being dive...

Page 6: ...nd vacuum the openings on your smoke alarm once a month 4 Do not open the smoke alarm or try to repair it For replacement information see the WARRANTY in the Owner s Manual 5 Verify you have the proper number of smoke alarms in your home and the correct location for each one A smoke alarm will not respond well in an incorrect location 6 If your smoke alarm has one or more of these special features...

Page 7: ...to stay close to the floor and crawl and how to use the alternate exit if a door is hot and should not be opened Decide on a meeting place a safe distance from your house and make sure all your children understand they should go and wait for you there if there is a fire Hold fire drills every six 6 months to make sure everyone even small children know what to do to escape safely Know where to go t...

Page 8: ...SMOKE ALARM PLEASE FOLLOW THESE DIRECTIONS 1 Unlock and remove mounting bracket from smoke alarm with a counterclockwise twist 2 Place mounting bracket on ceiling or wall in prearranged location and use pencil to trace two opposing hole positions for mounting screws Drill two 1 16 inch holes 3 Use mounting screws provided for attaching to studs or woodwork For plaster or plasterboard you may wish ...

Page 9: ...e Use a soft brush or wand attachment and vacuum all slots in the cover and side FOR YOUR SAFETY you must properly clean and maintain your smoke alarm since a dirty or malfunctioning unit may fail to alarm or cause unwanted nuisance alarms If the unit is damaged or fails to operate properly and you have checked that a good battery is installed correctly follow the directions in the section WHERE T...

Page 10: ...or Duracell M15HD MN1500 CAUTION DO NOT USE ANY TYPE OF RECHARGEABLE BATTERIES USING THE TAMPER RESIST LOCKING MECHANISM To make the smoke alarm somewhat tamper resistant a locking pin has been provided in the base of the unit It will help deter a child or other individual from removing the smoke alarm from the bracket See Figure 7 This can be installed by the following directions 1 Remove the bre...

Page 11: ...ull normal sensitivity If a real fire occurs however and the quantity of smoke reaching the smoke alarm is sufficiently great the unit will sound an alarm The Reduced Sensitivity level is only intended to eliminate nuisance alarms caused by light concentra tions of smoke If additional Reduced Sensitivity time is required push the button again Every time the smoke alarm is tested it will enter the ...

Page 12: ...OKE ALARM AND TEN 10 YEARS FOR THE ULTRALIFE LITHIUM U9VL J 9 VOLT BATTERY WHEN SOLD WITH MAPLE CHASE SMOKE ALARM FROM PURCHASE DATE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL MAPLE CHASE COMPANY BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMP...

Reviews: