Firenado

 Spiral Vented Gas Log Burner Owner’s Manual (FN-SGLBV24-NG) 

 

USE ONLY IN A FULLY FUNCTIONAL WOOD-BURNING FIREPLACE WITH DAMPER FIXED IN THE FULLY 

OPEN POSITION. FIREPLACE REQUIRES ABLILITY TO BURN SOLID FUEL AND MUST BE PROPERLY VENTED 

WITH A FUNCTIONING FLUE MADE OF NONCOMBUSTIBLE MATERIAL. ALL PRODUCTS OF COMBUSTION 

MUST BE VENTED. PROPANE MUST NOT BE USED – NATURAL GAS ONLY! 

 

 

 

ATTENTION 

INSTALLER:

 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE CONSUMER. 

CONSUMER: PLEASE READ & RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE AND BEFORE 

INSTALLING OR OPERATING.  

 

 

WARNING 

 

If the information in this manual is not followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life. 

 

 

WARNING 

Do not store or use combustible materials, gasoline or other flammable vapors and liquids in the  

vicinity of this or any other appliance. 

WHAT TO DO IF YOU SMELL GAS: 

 

Shut off gas to the burner. 

 

Extinguish any open flame. 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use any phone in your building. 

 

Exit the building and immediately call your gas supplier. Follow your gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire department. 

 

 

WARNING 

 

Read the installation, operation, and maintenance instructions thoroughly before installing, 

operating or servicing this equipment to reduce risk of fire, burn hazard or other injury.  

 

This manual should be retained for your information.  

 

Do not operate this burner without having read this manual.  

 

All gas installations, service and repairs must be performed by a qualified technician or authorized 

service agent. 

 

NOTE: This burner is not intended for commercial use. 

 

 

IMPORTANT 

 

This burner is intended for use in a fully functional wood-burning fireplace in good repair. This 

means the chimney has been inspected and works properly. 

 

The damper must be in the fully open position at all times during operation. The flue and fireplace 

must be constructed of noncombustible materials and vent all products of combustion to ensure  

the safety of use. 

Summary of Contents for FN-SGLBV24-NG

Page 1: ... any open flame Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Exit the building and immediately call your gas supplier Follow your gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Read the installation operation and maintenance instructions thoroughly before installing operating or servic...

Page 2: ...d service of the burner Proper location and proper use is essential to insure safe and continued trouble free operation Any non approved alterations made to the fireplace burner will void the product s warranty NOTE The manufacturer cannot be held responsible for damage or injury caused by improper use or installation of this burner IMPORTANT Consult the AHJ Authority Having Jurisdiction or local ...

Page 3: ...ll be HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING COULD IGNITE CAREFULLY SUPERVISE children in areas where the fireplace is located during and after operation Alert children and adults to hazards of high temperatures Clothing or other flammable materials should not be near the fireplace ADDITIONAL WARNINGS Please read all instructions before installing or operating your burner to prevent inj...

Page 4: ...never be allowed to touch sit or stand on any part of the burner Wear proper clothing when operating this burner Loose fitting or hanging garments should never be worn while using the burner Do not leave the burner unattended while in use Do not leave the burner in use while sleeping If glass doors are present always operate with doors in the fully opened position When the gas valve is in the OFF ...

Page 5: ... burner must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The burner and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system The minimum inlet natural gas suppl...

Page 6: ... cleaned cleared of any soot ashes creosote loose paint and or debris Consult a fireplace inspecting professional as well as a chimney cleaning professional Free opening area of chimney damper for venting combustion products factory built fireplaces Chimney Height Ft Appliance Input Rate kBTU hr Minimum Opening Sq In 20 110 50 25 110 45 30 110 39 35 110 36 40 110 33 Height is from hearth to top of...

Page 7: ...ription Part Tool List Firenado Burner 1 Crescent Wrench x2 Grate 2 Long Flathead Screwdriver 12 Non Whistling Flex Connector 3 Leak Checker Soapy Water 3 8 Inch Elbow Fitting 4 Gas Approved Pipe Sealing Compound 1 2 Inch Elbow Fitting 5 or Gas Approved Teflon Tape NG Orifice Fitting 6 Heat Resistant Gloves Gas Cap 7 Pencil Damper Clamp 8 Pipe Wrench Sand Granule Pack 9 Long Fireplace Matches Glow...

Page 8: ...as connection inside the wall Remove the log lighter gas cap and or fittings leaving just the main gas feed line Assemble the gas connections onto the burner The gas log burner is designed to accept the gas supply from either the right hand or the left hand side of the burner to adjust to the side of the fireplace in which the gas comes in Install the straight gas orifice fitting on the gas supply...

Page 9: ... the connection points Correct any leaks before proceeding Fill the burner with the included sand granules Slope the sand with the shape of the burner tapering it from the front to the back Avoid spilling the sand outside of the pan as much as possible Cover the burners completely Do not pat down Note you may have extra sand when done See Figure A Install the glowing ember material to the top of t...

Page 10: ...ticed in the room soot at the top of the fireplace opening soot directly above the fireplace soot on the underside of the fireplace mantel and or soot anywhere in the room Discontinue use of the gas log set immediately until the issue has been properly corrected by a certified chimney professional OPERATING YOUR BURNER Before Lighting Smell at and around the burner and fireplace area and next to t...

Page 11: ...anywhere in the room Discontinue use of the gas log set immediately until the issue has been properly corrected by a certified chimney professional Sooting on logs Some sooting of the logs can be expected but excessive sooting can be caused by the following items high gas pressure logs may be placed tightly together not allowing a path for fire and draft to move through or fireplace venting system...

Page 12: ...with warranty parts All warranty claims are subject to manufacturer review Please make sure to have your sales receipt information All replacement parts can be purchased through your local stocking dealer This warranty is intended for the original purchaser and is nontransferable WHAT IS NOT COVERED Cost of removal and or reinstallation Shipping and or transportation cost Service calls to determin...