background image

K & W Manufacturing Co., Inc.,

 23107 Temescal Canyon Road, Corona  CA  92883

951-277-3300 Phone     951-277-2070 FAX     www.k-and-w-mfg.com

Series 1000
Heat Circulating Fireplace
Installation Instructions

Dimensions

Model 

No.

Heating 

Capacity 

(Cu. Ft.)

A

B

C

D

E

F

G

H

Min.

J

Min.

K

L

1034A

5300

33

27

22.75

16.5

39.5

21.5

51.5

65

30

12

12

1037A

5800

36

27

25.75

16.5

42.5

21.5

51.5

68

30

12

12

1042A

6400

41

27

30.75

16.5

47.5

21.5

51.5

73

30

16

12

1048A

7600

47

29.5

36.75

20.5

53.5

25.5

55.5

79

38

20

16

1060

9500

59

29.5

48.75

24.5

67.5

29.5

65.5

91

43

20

20

1072

10600

71

29.5

60.75

24.5

79.5

29.5

65.5

103

43

20

20

Heating capacity ratings based on 20

F above zero.

 

All dimensions are in inches unless stated otherwise.

Made from Heavy Gauge Steel
Poker or Optional Rotary Control

Conforms with IBC

®

 & IRC

®

Insulation provided to prevent 
masonry cracking

Page 1 of 6

Summary of Contents for Series 1000

Page 1: ...A 5800 36 27 25 75 16 5 42 5 21 5 51 5 68 30 12 12 1042A 6400 41 27 30 75 16 5 47 5 21 5 51 5 73 30 16 12 1048A 7600 47 29 5 36 75 20 5 53 5 25 5 55 5 79 38 20 16 1060 9500 59 29 5 48 75 24 5 67 5 29 5 65 5 91 43 20 20 1072 10600 71 29 5 60 75 24 5 79 5 29 5 65 5 103 43 20 20 Heating capacity ratings based on 20o F above zero All dimensions are in inches unless stated otherwise Made from Heavy Gau...

Page 2: ...masonry measurements Use these plans and charts to determine the masonry footprint of this particular installation The foundation should extend a minimum 6 beyond the masonry footprint on all sides It should be 12 or more in thickness depending on local conditions Check your local building codes The foundation should be poured concrete or solid masonry It is recommended that it be reinforced with ...

Page 3: ...and the following page show alternative fireplace configurations that can be achieved with a Fire Magic heat circulating fireplace Model No A H Min J Min 1034A 33 53 30 1037A 36 56 30 1042A 41 61 30 1048A 47 67 38 1060 59 79 43 1072 71 91 43 Drawings and dimensions depicting a fireplace that projects into the room with air inlets and outlets on the sides Two elevations are shown one with the outle...

Page 4: ...llation Instructions Page 4 of 6 Alternative Configurations continued Drawing and dimensions depicting two fireplaces set side by side Model No A H Min J Min 1034A 33 120 30 1037A 36 126 30 1042A 41 136 30 1048A 47 148 38 Drawing and dimensions depicting two fireplaces set back to back Model No A H Min J Min 1034A 33 65 56 1037A 36 68 56 1042A 41 73 56 1048A 47 79 72 ...

Page 5: ... ducts and their passageways is 1 inch The exterior air intakes may not be located at an elevation higher than the firebox The air intakes must pull the combustion air from the exterior of the dwelling or from spaces within the dwelling ventilated with outside air such as non mechanically ventilated crawl or attic spaces The exterior air intakes may not be located within the garage or basement of ...

Page 6: ...ess than the circulating fireplace opening to conceal the joint between the masonry and metal This joint should be packed with insulation Remember to allow for the openings for the air inlets and outlets Chimney and Flue Chimney and flue construction is the same as any other fireplace Either a masonry or a metal chimney may be used with a Fire Magic circulator It is important to note the flue whet...

Reviews: