background image

FHH10W

READ AND RETAIN THIS USER MANUAL

5. TESTING THE SYSTEM

Test the full system using the test button of the alarms and or Deaf Alerts if 
fitted.
1.  Undo the alarm from the pattress without 

disconnecting the wires and permanently 
attach it to the chosen location.  
See sec 4 para 2 above.

2.  Fit all alarms to their own Radio Pattresses 

by lining up as shown here:

3.  Close the alarm onto the Radio Pattress 

and turn the alarm clockwise to lock it into 
place. This action automatically turns the 
alarm on.

Press the test button on each alarm and wait for the other alarms to sound 
before testing all other alarms in the same way. The alarm should sound 
three times with a flashing red light then stop. Allow at least 5 seconds after 
a successful test before testing the next one. After testing check that the 
red light flashes approximately every minute. Test the alarm once a week to 
ensure correct operation.
The 

Radio Interlinked System

 is now ready for use. 

Do not change any components of the system for those made by other 
manufacturers. Up to 15 alarms may be paired to the system.

WARNING: 

The electronic test button provides a full test of the alarms 

functionality. Do not try to test the alarm using either heat smoke or naked 
flame as damage will occur.

6. USER INFORMATION

 

Protect your Home Against Fire

 

Contact your local Fire Brigade for a home safety check, this information is 
free and will identify potential fire hazards in and around your home.
Make sure all occupants of the home know what a fire alarm sounds like. 
Prove and practise a fire escape plan and arrange a suitable and safe assembly 
point.

What to Do if the Alarms Sound 

 

Alarms sounds are as follows:


 

  Full alarm indicating  Repeating series of 3 beeps every 

•••  •••  ••• ••• 

 

smoke and fire 

4 seconds with flashing light

 

Low Battery 

Single beep every minute 

•      •      •      •

  Test button jammed 

One beep every 11 seconds 

•      •      •      •

 

Fault 

Double beep every minute 

••    ••    ••    ••

Ensure everyone leaves the building as soon as possible.
• Do not run.
• Do not stop to collect belongs.
• If it is safe to do so, close all windows and doors as you escape to prevent 

the spread of fire.

• Smoke is the main cause of death from fire. If trapped inside the building, 

cover your mouth, conserve breath and crawl to safety.

Do not silence a fire alarm until you know the cause of the alarm 

and when all occupants are safely outside the building.
Silencing an alarm 

 

Do not silence a smoke alarm until you are certain there is no fire. The fire 
alarm that has detected a fire will be flashing its red light in the centre of 
the test button once every second, all other alarms in the system will just be 
sounding. 
To silence the fire alarm system, press the test button on any alarm in that 
system. If one alarm continues to sound, it will be the one that has detected 
a fire. Check for a fire in its area and for its flashing red light. ONLY if you are 
certain there is no fire, press its test button to silence it. If you are not certain, 
evacuate the property and call your fire and rescue service on 999.

7. ALARM MAINTENANCE

 

A regular program of fire alarm maintenance will help to keep your alarm in good 
working order.
• Test the alarm weekly making sure that all interconnected alarms in the 

system sound within 10 seconds.

• Vacuum the alarms every six months and wipe them with a damp cloth.
• Do not paint the alarm.
A fire alarm is a sensitive life-saving device. The life of this alarm can be 
significantly reduced by adverse environments, incorrect location and a failure 
to regularly clean and maintain it according to the instructions. Incorrect 
location and a lack of reasonable care may also cause it to malfunction and 
will invalidate the warranty.

8. TROUBLE SHOOTING

The battery in the alarm will last ten years and the battery in the pattress will 
last seven years - they are both non-replaceable. At the end of its life the 
alarm will beep once every minute for a minimum of one month.
The life of the battery can be significantly shortened by periods of storage 
or use in temperatures below 5°C or above 30°C. It will also be shortened 
by frequent or extended periods in full alarm often caused by conditions 
such as cigarette smoke, steam, aerosol spray and condensation. In these 
circumstances the warranty will be void.
If this happens at night you can press the test button to silence the battery 
warning for 10 hours. Replace the alarm as soon as possible.
Problems are indicated in five ways;
1.  The alarm beeps twice every minute indicating a malfunction.
2.  The alarm beeps once every minute indicating a low battery.
3.  The full alarm sounds for no reason. (A repeating series of three beeps with 

flashing light)

4.  The alarm does not sound when pressing the test button.
5.  The test button light remains steadily on or off. (i.e. does not flash 

approximately once every minute, when the unit is not in alarm)

Inspect for obvious damage. Check that the alarm has been installed in 
accordance with the instructions. In the case of repeated nuisance alarms, 
check that it is free from dust, cobwebs and external contamination from 
such things as cigarette smoke, drying paint, spray from household aerosols 
and steam that will ultimately shorten the life of the alarm and invalidate the 
warranty.
If this does not correct the problem, do NOT attempt to repair. There are 
no user serviceable parts internally. If the smoke alarm is within the warranty 
period and terms, indicate the nature of the problem and return the unit with 
proof of purchase to the address at the end of this manual. Units beyond 
warranty cannot be economically repaired.

9. PRODUCT WARRANTY

Fireblitz guarantees to you, as a purchaser, that the enclosed fire alarm will be 
free from defects in material, workmanship or design under normal use and 
service for a period of 10 years. The enclosed Radio Pattress is guaranteed 
for 7 years. These Guarantees are not assignable. Our liability to you, under 
this guarantee is limited to repairing or replacing any part which we find to be 
defective in material, workmanship or design, free of charge to the customer, 
upon sending the alarm with proof of date of purchase, postage paid to 
Fireblitz Extinguisher Ltd, Units 15/17 Manford Industrial Estate, Manor Road, 
Erith, Kent DAB 2AJ. The terms of this guarantee will not apply in the following 
circumstances:
• If the alarm has been modified, dismantled, contaminated, damaged, 

neglected or otherwise abused or altered following the date of purchase,

• If it fails to operate due to incorrect siting, installation or maintenance
• Damage caused by failure to abide by the instructions supplied.
It is specifically drawn to the users attention that substantial periods in alarm 
will shorten alarm life, during which time the fire alarm will have provided 
valuable protection; no Claim under the guarantee will be entertained. The 
liability of Fireblitz Ltd, arising from the sale of this alarm or under the terms 
of this guarantee shall not in any case exceed the cost of replacement of the 
alarm. In no case, shall Fireblitz Ltd be liable for consequential loss or damage 
resulting from the failure of the alarm or the breach of this or any other 
guarantee, express or implied or for damage caused by failure to abide by the 
instructions supplied.
This guarantee does not affect your statutory rights.

Fireblitz Extinguisher Ltd.

 

Units 15-17 Manford Industrial Estate,  

Manor Road. Erith, Kent DA8 2AJ

Telephone: 01322 342238 

TECHNICAL HELPLINE 0800 008 6568

Text on 07885 831239

Email: [email protected]

7

YEAR 

WARRANTY

MANUAL

 WIRELESS (RADIO LINKED)

Heat Alarm

10 YEAR LITHIUM BATTERY OPERATED

BS5446-2:2003

Licence number 

KM654703

Reviews: