PRODUCT OVERVIEW
This alarm is a smoke detector of the photo cell
principle. This means that the alarm checks the air for
smoke resulting from fire. It does not detect heat, gas
or fire. If the smoke detector is properly mounted and
maintained it will sound an alarm in an early stage. In
the event of a fire this can give you those extra seconds
needed to vacate your home and call the fire brigade.
The alarm is designed to detect smoke. It cannot
prevent a fire. Read the instructions through carefully
before using the smoke detector.
FG-S01_AP / FG-S02_AP / FG-SO3_AP
SMOKE DETECTORS
Photoelectric sensing technology
Easy installation and maintenance
Battery case at the back of a sensor for easy
removal of a battery
Sleek low-profile housing design
Low battery warning
Test button verifies battery and alarm
operation
Sounding a loud alarm signal or exceeding
85db in alarm mode
Features
MODEL
FG-S01_AP / FG-S02_AP /
FG-S03_AP
DESCRIPTION
Smoke Detectors
FIREGUARD GLOBAL LTD.
00-44-8450751042
00-44-8459751043
Smoke Sensitivity :
0.086 dB/m to 0.14 dB/m
Power Supply :
9V Carbon Zinc/Alkaline
Lithium Battery
Battery Life :
>12 months
Low Battery Life :
>30 days
Alarm Indicator :
Continuously emitting red
light and alarm sound
Alarm Sound Level :
>85dB at 10 feet (3m)
Temperature :
0ºC - 50ºC
Humidity :
10%-90%RH, no
condensation or icing
Dimensions (LxWxH) :
FG-S01/FG-S02: ø107x35mm
FG-S03: ø130x40mm
Technical Specification
FG-S01
FG-S02
FG-S03
IMPORTANT
Placing a smoke alarm is a part of your fire
protection, just as fire extinguishers, emergency
ladders, ropes, but also your choice in the use of
building materials for renovation. Always ensure
that there is an evacuation plan, discuss this with
your children. Ensure that each room can be left