Firegear REVOLUTION L-360-RR SERIES Placement Instructions Download Page 1

 

1

DECORATIVE GAS LOG 
PLACEMENT INSTRUCTIONS 

 

REVOLUTION L-360-RR & L-420-RR  

ROARING RED VENT-FREE LOG SERIES 

 

If for any reason, you cannot follow these instructions, 

FOR 

ANY REASON WHATSOEVER

, just return the product to your 

dealer, and the dealer will refund your money. 

 “PLEASE”

 do 

not use this product if you cannot follow these instructions.  

   

GENERAL INFORMATION 

 

BEFORE YOU BEGIN! 

READ THE HEARTH KIT INSTRUCTION MANUAL, 

FURNISHED WITH THE APPLIANCE. 

 

FOLLOW ALL SAFETY AND SET UP PROCEDURES! 

 

These instructions are intended as a general guide and do not 
supersede national or local codes in any way.  State or local 
codes may only allow operation of this appliance in a vented 
configuration.  Check your state or local codes.  Authorities 
having jurisdiction should be consulted before installation. 

 

!!! IMPORTANT !!! 

Read these instructions carefully before installing or operating 
this gas appliance.  These instructions should be left with the 
homeowner for future reference. 

INSTALLER:

 Leave this manual with the appliance. 

CONSUMER:

 Retain this manual for future reference. 

 

!!! WARNING !!! 

If the information in this manual is not followed exactly, a 
fire or explosion may result causing property damage, 
personal injury or loss of life.

 

 

 

 

 

  

15LP 

 

!!! WARNING !!! 

Failure to position the parts in accordance with all included 
pictures, diagrams, and drawings, or failure to use only parts 
specifically approved with this appliance may result in property 
damage or personal injury.  DO NOT apply any extra material 
or gas logs not furnished with this appliance. 

 

!!! WARNING !!! 

The position of the gas logs is critical to the safe and clean 
operation of this appliance.  Sooting and other problems may 
result if the gas logs are not properly, and firmly positioned on 
the appliance. 

 

!!! IMPORTANT !!! 

This appliance is supplied with eleven (11) decorative gas 
logs.  Handle all gas logs with care and, it is our 
recommendation that you use gloves during the set up 
procedures. 

 

 

 
 

ANSI Z21.11.2 – (2002) STANDARD FOR GAS-FIRED 
UNVENTED ROOM HEATERS (US ONLY).  15LP 

 

Summary of Contents for REVOLUTION L-360-RR SERIES

Page 1: ...tructions should be left with the homeowner for future reference INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manu...

Page 2: ...G REV 2408 RR L 360 RR L 420 RR DECORATIVE GAS LOG SERIES INDIVIDUAL LOGS continued LOG REV 2409 RR LOG REV 2410 RR LOG REV 2411 RR or REV 3011 RR L 360 RR L 420 RR DECORATIVE GAS LOG SERIES ACCESSORY...

Page 3: ...LATION SEQUENCE L 360 RR L 420 RR 1 Place Log REV 2401 RR REV 3001 RR on L 420 RR on the rear of the grate burner assembly making sure to index the bottom of the log on the grate tines FRONT ANGLE VIE...

Page 4: ...Place Log REV 2402 RR on the front left side of the grate burner assembly making sure to index the front left two 2 grate tines NOTE Be sure the rear of the log is perpendicular to the grate and DOES...

Page 5: ...2403 RR REV 3003 RR on L 420 RR on the front right side of the grate burner assembly making sure to index the front right three 3 grate tines NOTE Be sure the rear of the log is perpendicular to the g...

Page 6: ...REV 2404 RR on the top left side of Log REV 2401 RR and Log REV 2402 RR making sure to index the locators on the two 2 base logs NOTE Be sure the rear of Log REV 2402 RR is perpendicular to the grate...

Page 7: ...REV 2405 RR on the top right side of Log REV 2401 RR and Log REV 2403 RR making sure to index the locators on the two 2 base logs NOTE Be sure the rear of Log REV 2403 RR is perpendicular to the grate...

Page 8: ...SEQUENCE L 360 RR L 420 RR continued 6 Place Log REV 2406 RR on the top center of Log REV 2401 RR and the top left of Log REV 2403 RR making sure to index the locators on the two 2 base logs FRONT ANG...

Page 9: ...ace Log REV 2407 RR REV 3007 RR on L 420 RR on the top rear of Log REV 2404 RR and top rear of Log REV 2405 RR making sure to index the locators on the two 2 base logs NOTE Log REV 2407 RR should fit...

Page 10: ...10 PROPER INSTALLATION SEQUENCE L 360 RR L 420 RR continued 8 Place Log REV 2408 RR with the Y around the grate tine and laying in the center locator of Log REV 2406 RR FRONT ANGLE VIEW OVERHEAD VIEW...

Page 11: ...11 PROPER INSTALLATION SEQUENCE L 360 RR L 420 RR continued 9 Place Log REV 2409 RR on the bottom front left corner of the grate burner assembly FRONT ANGLE VIEW OVERHEAD VIEW...

Page 12: ...12 PROPER INSTALLATION SEQUENCE L 360 RR L 420 RR continued 10 Place Log REV 2410 RR on the bottom front right corner of the grate burner assembly FRONT ANGLE VIEW OVERHEAD VIEW...

Page 13: ...REV 3011 RR on L 420 RR on the bottom center of the grate burner assembly making sure to index the grate tine and the locator on the bottom of the log to the metal tab mounted to the bottom front lip...

Page 14: ...er Log REV 3011 RR FG LAK ADD LOGS FG LAK Log One LAK 01 FG LAK Log Two LAK 02 FG LAK Log Three LAK 03 FG LAK Log Four LAK 04 FG HAK ADD LOGS FG HAK Log One HAK 01 FG HAK Log Two HAK 02 FG HAK Log Thr...

Page 15: ...d This Limited Warranty does not cover any failures or operating diRRiculties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service...

Page 16: ...16 www firegearusa com L360RR 1 0...