background image

Linear All Weather System (AWS) Fire Pits

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

 

This fire pit requires a minimum 18-square inches (per side) of cross ventilation. 

Failure to provide proper ventilation can void the warranty.

Models: NG/LP

Description

LOF-2412HAWS-N/P

24” x 12” Fire Pit with H-Burner

LOF-3012HAWS-N/P

30” x 12” Fire Pit with H-Burner

LOF-3614HAWS-N/P

36” x 14” Fire Pit with H-Burner

LOF-4814HAWS-N/P

48” x 14” Fire Pit with H-Burner

LOF-6016HAWS-N/P

60” x 16” Fire Pit with H-Burner

LOF-7216HAWS-N/P

72” x 16” Fire Pit with H-Burner

LOF-8416HAWS-N/P

84” x 16” Fire Pit with H-Burner

LOF-9616HAWS-N/P

96” x 16” Fire Pit with H-Burner

MODELS

H-Burner

T-Burner

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

MODEL:
SERIAL #:

PN#90136

Models: NG/LP

Description

LOF-2406TAWS-N/P

24” x 6” Fire Pit with T-Burner

LOF-3006TAWS-N/P

30” x 6” Fire Pit with T-Burner

LOF-3606TAWS-N/P

36” x 6” Fire Pit with T-Burner

LOF-4806TAWS-N/P

48” x 6” Fire Pit with T-Burner

LOF-6006TAWS-N/P

60” x 6” Fire Pit with T-Burner

LOF-7206TAWS-N/P

72” x 6” Fire Pit with T-Burner

LOF-8406TAWS-N/P

84” x 6” Fire Pit with T-Burner

LOF-9606TAWS-N/P

96” x 6” Fire Pit with T-Burner

Summary of Contents for LOF-2406TAWS-N

Page 1: ... 48 x 14 Fire Pit with H Burner LOF 6016HAWS N P 60 x 16 Fire Pit with H Burner LOF 7216HAWS N P 72 x 16 Fire Pit with H Burner LOF 8416HAWS N P 84 x 16 Fire Pit with H Burner LOF 9616HAWS N P 96 x 16 Fire Pit with H Burner MODELS H Burner T Burner DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL PN 90136 Models NG LP Description...

Page 2: ...partment DANGER WARNING Do not store or us gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adj...

Page 3: ...ture differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken wh...

Page 4: ...16HAWS P 84 x 16 2133 x 406mm 86 x 18 2197 x 469mm 81 x 10 2057x 254mm 85 x 17 2159 x 330mm 8 203mm 8 203mm 120 3048mm 18 457mm LOF 9616HAWS N LOF 9616HAWS P 96 x 16 2438 x 406mm 98 x 18 2501 x 469mm 93 x 10 2362 x 254mm 97 x 17 2463 x 330mm 8 203mm 8 203mm 120 3048mm 18 457mm Fig 1 H style burner pan specifications SPECIFICATIONS Model N Natural P Propane Natural Orifice Btu Ratings Propane Orifi...

Page 5: ... x 178mm 8 203mm 36 914mm 120 3048mm 18 457mm LOF 9606TAWS N LOF 9606TAWS P 96 x 6 2438 x 152mm 98 x 8 2501 x 215mm 93 2362mm 97 x 7 2463 x 178mm 8 203mm 36 914mm 120 3048mm 18 457mm SPECIFICATIONS Model N Natural P Propane Natural Orifice Btu Ratings Propane Orifice LOF 2406TAWS N LOF 2406TAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 3006TAWS N LOF 3006TAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 36...

Page 6: ...a around the pipe with weather sealant Consult a plumber for proper installation to ensure you are providing adequate gas supply for your application 4 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line not supplied with the fire feature see Fig 5 page 9 5 Do not place an LP tank inside any fire pit enclosure Locate al...

Page 7: ...ired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 ...

Page 8: ...ase of the orifice to provide a cleaner flame See Fig 5 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to installing the wire nut This will ensure a waterproof connection Why GFI circuit A GFI is a type of circuit breaker ...

Page 9: ...l Line Gas Line ON OFF or or Main Burner Flat Pan Pilot Burner Min 12 gauge Flex Frame shown in detail enables the ability to remove the pan disc to service valve system Flex Frame Min Max Distance Pilot Run 6 to 22 Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Control Pool Certified Applications Fire Feature within 5 feet of pool or spa...

Page 10: ...er Use dielectric grease on all wire nut connections and connectors to prevent moisture issues from the outdoor environment Fig 8 Shows carton contents Note H burner was illiustrated for this drawing The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the adapter When wiring the remote control receiver one red wire from the receiver connects to the adapter w...

Page 11: ...d Red Red Red Black Red Black Red Sleeve FG 1420 AOD Receiver GOE 30VDC Power Supply Heat Shield 120VAC Power GFI Outlet Orifice Fig 10 Shows typical installation of fire pit using AWS system LEARN Weather Proof Box AWS Valve Box GFI Box Adapter Weather Proof Box Red R e d R e d Red Black Black Red Red Black Antenna Red Sleeve Fig 9 Wire diagram of AWS system with 1420 A remote control receiver ...

Page 12: ... Cover the burner completely with media but do not make the depth greater than 1 inch overtop of the burner port holes Do NOT cover the top of the screen hood with any rock or glass It must be free an any debris to operate properly Media Required Per H Burner Models N Natural P Propane Lava Rock Only Glass Only Lava Stones Only LOF 2412HAWS N P 10lbs 15lbs 10lbs LOF 3012HAWS N P 15lbs 20lbs 15lbs ...

Page 13: ...evere burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING AND THE TRANSMITTER AND RECEIVER HAVE BEEN LEARNED PROGRAMED TOGETHER FOR WIRELESS OPERATION WARNING Do not stand over fire pit during ignition or operation due to high surface temperatures LIGH...

Page 14: ...REV C Page 14 Drop in Pan AWS Fire Pits AWS REPLACEMENT PARTS 1 2 6 7 5 Drawings not to scale 4 3 8 14 9 11 10 12 13 15 10a OUT GOE 30DCV Junction Box Weatherproof Cover Lid 7A ...

Page 15: ... with 27 T burner 1 78033 3 36 x 6 LT Burner Pan Only use with 33 T burner 1 78034 3 48 x 6 LT Burner Pan Only use with 45 T burner 1 78035 3 60 x 6 LT Burner Pan Only use with 57 T burner 1 78036 3 72 x 6 LT Burner Pan Only use with 69 T burner 1 78037 3 84 x 6 LT Burner Pan Only use with 81 T burner 1 78058 3 96 x 6 LT Burner Pan Only use with 93 T burner 1 78061 4 21 T Burner Only used with 24 ...

Page 16: ...downpours could affect the fire pit operation if not covered if this occurs ensure you allow the fire pit time to dry out before attempting to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Carbon soot may build up on the surface of logs if installed during heavy use Sooting may also occur...

Page 17: ...nverting Natural gas burners to LP gas the main burner orifice must be kept a minimum of 6 inches away from the burner connection nipple to prevent any back pressure at the LP orifice See Fig 12 below for details Note It is acceptable to install a 90 elbow if necessary to run the gas line the opposite direction see Fig 13 or 14 A 90 elbow is not provided with the kit Note Pilot conversion kit FG A...

Page 18: ...cted 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector Not Plugged In Correctly Check the 2 Pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If loose push the...

Page 19: ...ermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then replace it De...

Page 20: ...t Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas will rise to the top of the feature Once it encounters the flame a flare up will occur Propane is heavier than air so if there is a gas leak...

Page 21: ...AVER VENT 6 LNTS Shut Off Valves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare LP Conversion Kit Model FG AWS PBO P Converts primary pilot orifice to LP gas Note In addition requires the main burner orifice to be changed to an L P orifice purchased separately from supplier See pages 4 5 for LP orifice Glass Windshields See...

Page 22: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Page 23: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Page 24: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 25: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 26: ...ental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Ph...

Page 27: ...REV C Page 27 Drop in Pan AWS Fire Pits NOTES ...

Page 28: ..._ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us w...

Reviews: