Firegear FPB-19RBSMT-N Installation And Operating Instructions Manual Download Page 3

REV. C  Page 3

MT Burning Spur Fire Pits

Specifications

4

Preparation for Non-Combustible Structure

5

     Hard Piping to Fire Pit

5

     Cross Ventilation Requirements

5

     High Elevation

5

Installation into an Approved Enclosure

6

    Requirements

6

    Installing Key Valve 

6

    Typical Installation Drawings

7

Operation

8

    

Lighting Instructions

8

Replacement Parts

9

Replacement Parts List/ Maintenance

9

Converting to LP Gas

11

Trouble Shooting

12

Optional Accessories

12

TABLE OF CONTENTS

NOTE:

  An exterior lid/cover is not required but highly recommended when the fire pit is not in 

use. Even though fire pits are designed for outdoors they are not impervious to all weather 

conditions if not protected.  See the accessory page for information and sizes.  

All media (i.e. lava rock, lava stones, lava boulders and fire glass) has the potential of thermal 

spalling.  This is a process that may occur when media is wet and moisture gets trapped inside of 

the material due to rapid temperature differences.  When this happens the media has the potential 

to crack or “pop” outside the fireplace.

WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE

The use of a cover can lessen the impact of thermal spalling; however, heavy rains, high 

humidity and the presence of moisture may still cause the media to pop.

ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE 

Extra caution should be taken when lighting a fireplace when heavy rains, high humidity and 

moisture are present.  Light the fireplace; leave the area allowing any moisture in the media to 

dissipate.  We strongly recommend that during this drying out time that you monitor the fire feature 

from a distance.  This drying out period should be no less than 30 minutes.  Continue monitoring 

the flame from distance to ensure that all popping has ceased before fully enjoying the fire. 

CALIFORNIA PROPOSITION 65

 

      WARNING

This product is designed to operate with one of the following fuel sources:  Liquid Propane or Natural Gas. The fuel 

used to operate this product, and the products of combustion of such fuel, can expose you to chemicals including 

Benzene which is known to the State of California to cause cancer, birth defects and other reproductive harm and 

Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm. 

(For more information go to: www.p65Warnings.ca.gov.)

Summary of Contents for FPB-19RBSMT-N

Page 1: ...escription FPB 19RBSMT N 19 Round Stainless Pan with 16 Burning Spur FPB 25RBS22MT N 25 Round Stainless Pan with 22 Burning Spur FPB 29RBS22MT N 29 Round Stainless Pan with 22 Burning Spur FPB 33RBS31MT N 33 Round Stainless Pan with 31 Burning Spur FPB 20SBSMT N 20 Square Stainless Pan with 16 Burning Spur FPB 26SBS22MT N 26 Square Stainless Pan with 22 Burning Spur FPB 32SBS31MT N 32 Square Stain...

Page 2: ...fire department WARNING Do not store our use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation a...

Page 3: ...GHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave ...

Page 4: ... 13 0 WC 3 23 kPa Normal Inlet 7 0 WC 1 74 kPa 11 0 WC 2 73 kPa Table 3 Gas Pressures Model N Natural Gas A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor Burner Size FPB 19RBSMT N 2 19 20 19 8 36 96 18 16 FPB 25RBS22MT N 2 25 27 25 8 36 96 18 22 FPB 29RBS22MT N 2 29 30 29 8 36 96 18 22 FPB 33RBS31MT N 2 33 35 33 8 36 120 18 31...

Page 5: ...anual shut off valve at the exterior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line supplied with the fire pit see Fig 5 page 7 IMPORTANT Installation of Natural or LP gas should be ...

Page 6: ...r outdoor use only Not approved for any indoor use 9 This fire pit is designed to have Firegear Outdoors lava rock completely covering the Spur burner so that the burner is not visible Do not cover more than 1 above the top of the covered burner When purchasing lava rock use 1 diameter as a base to fill the burner pan 10 Gas lines and fittings must be installed in to the non combustible structure ...

Page 7: ... Valve Primary Gas Supply Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall...

Page 8: ...fore each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 7 Inserting Key into Valve O N O F F Fig 6 Key Valve Face Butane L...

Page 9: ...REV C Page 9 MT Burning Spur Fire Pits MT REPLACEMENT PARTS 1 2 6 3 8 7 5 4 9 10 Drawings not to scale O N O F F 11 12 13 14 8a ...

Page 10: ...ce Propane Gas 250 000 Btu s 1 OAS LP12 9 10 24 x 1 2 Type F Screw 304 SS not shown 4 10759 10 Key Valve 1 BVL2S 11 12 Inch Chrome Key 1 KEY PC 12 12 Chrome Cover Plate 1 CVR BVL2CP 13 NPT Male to Male Flare Fitting 1 U1 8D S 14 NPT Female to Male Flare Fitting 1 U3 8D S Item Description Qty Part Number MT REPLACEMENT PARTS 1 The fire pit should be inspected and cleaned before initial use at least...

Page 11: ...ig 10 or 11 A 90 elbow is not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8...

Page 12: ...rainage for water and proper ventilation to dry out ACCESSORIES The following accessories are available from your local Firegear dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing Stainless Round Lid for 19 33 Pits Models LID 19R2 LID 25R2 LID 29R2 LID 33R2 Stainless Square Lid for 20 38 Pits Models LID 20S LID 26S LID 32S...

Page 13: ... S U1 8D S Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 14: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Page 15: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Page 16: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 17: ... units Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 14520 ...

Page 18: ... Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us when...

Reviews: