Firegear FPB-19RBSMT-N Installation And Operating Instructions Manual Download Page 16

REV. C  Page 16

MT Burning Spur Fire Pits

The end-user must provide a bill of sale, canceled check, or payment record to verify the purchase date and to 

establish the warranty period. This Limited Warranty shall be valid and limited to the original purchaser only. 

 

WARNING

    Any modification to the product will void the warranty. 

This Limited Warranty shall be limited to the repair and/or replacement of parts that have been proven to be 

defective under normal use and service. All warranty claims must be made by the OEM/Distributor/Dealer 

account on behalf of the end-user. You may contact Technical Support at 800-966-8126. 

 

Our Technical Service Department must confirm all approved defects. If a defect is confirmed and we approve 

the claim, we will replace such parts without charge. This warranty gives you specific legal rights, and you may 

also have other rights, which vary from state to state. 

The manufacturer may request defective products returned with an RMA (Return Merchandise Authorization) 

issued by Firegear Outdoors for specific products, which is considered to be the nature of the defect and or 

warranty claim. Product to be returned should; be packed so as not to incur damages during transportation. 

Firegear is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date 

issued. The RMA must be clearly marked on the outside of the package. 

 

Please check with your local building code department or governing agency for proper approvals before 

purchasing. Firegear Outdoors is not responsible for any violation of local codes. 

 

Travel, diagnostic cost, service labor to repair the defect on warranty parts to and from the factory will be the 

responsibility of the owner.  We will not be responsible for labor charges and/or damage incurred in 

installation, repair, and replacement.  Firegear is not responsible for Issues related to gas or electrical 

installation.   

 

The Limited Warranty is voided if not assembled, installed, and operated as intended. This Limited Warranty 

does not cover any defects due to accident, abuse, misuse, alteration, misapplication, vandalism, improper 

installation or improper maintenance or service, removal from the original location, or re-installation into 

another location, or failure to perform normal and routine maintenance. 

 

Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, discoloration due 

to overheating, exposure to chemicals (including chlorine and salt), either directly or in the atmosphere, or 

very high humidity, is not covered by this Limited Warranty. Costal, humid and/or salt environments are 

subject to manufacturer review. All out-of-box claims must be made within 30 days of purchase and must be 

made prior to installation. Any product installed damaged will be considered damaged during installation and 

not covered under warranty. 

 

There are no other express warranties except as set forth herein. For consumer applications, any applicable 

implied warranties of merchantability and fitness are limited induration to the period of coverage of this 

Limited Warranty. Some states do not allow limitation on how long an implied warranty lasts, so this limitation 

may not apply to you. 

 

For Commercial Applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. 

We expressly disclaim any and all implied warranties, including any warranties of fitness for a particular 

purpose or merchantability. 

 

Summary of Contents for FPB-19RBSMT-N

Page 1: ...escription FPB 19RBSMT N 19 Round Stainless Pan with 16 Burning Spur FPB 25RBS22MT N 25 Round Stainless Pan with 22 Burning Spur FPB 29RBS22MT N 29 Round Stainless Pan with 22 Burning Spur FPB 33RBS31MT N 33 Round Stainless Pan with 31 Burning Spur FPB 20SBSMT N 20 Square Stainless Pan with 16 Burning Spur FPB 26SBS22MT N 26 Square Stainless Pan with 22 Burning Spur FPB 32SBS31MT N 32 Square Stain...

Page 2: ...fire department WARNING Do not store our use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation a...

Page 3: ...GHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave ...

Page 4: ... 13 0 WC 3 23 kPa Normal Inlet 7 0 WC 1 74 kPa 11 0 WC 2 73 kPa Table 3 Gas Pressures Model N Natural Gas A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor Burner Size FPB 19RBSMT N 2 19 20 19 8 36 96 18 16 FPB 25RBS22MT N 2 25 27 25 8 36 96 18 22 FPB 29RBS22MT N 2 29 30 29 8 36 96 18 22 FPB 33RBS31MT N 2 33 35 33 8 36 120 18 31...

Page 5: ...anual shut off valve at the exterior house wall If pipe is to pass through a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line supplied with the fire pit see Fig 5 page 7 IMPORTANT Installation of Natural or LP gas should be ...

Page 6: ...r outdoor use only Not approved for any indoor use 9 This fire pit is designed to have Firegear Outdoors lava rock completely covering the Spur burner so that the burner is not visible Do not cover more than 1 above the top of the covered burner When purchasing lava rock use 1 diameter as a base to fill the burner pan 10 Gas lines and fittings must be installed in to the non combustible structure ...

Page 7: ... Valve Primary Gas Supply Key Valve Side View Det a i l Fig 5 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall...

Page 8: ...fore each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 7 Inserting Key into Valve O N O F F Fig 6 Key Valve Face Butane L...

Page 9: ...REV C Page 9 MT Burning Spur Fire Pits MT REPLACEMENT PARTS 1 2 6 3 8 7 5 4 9 10 Drawings not to scale O N O F F 11 12 13 14 8a ...

Page 10: ...ce Propane Gas 250 000 Btu s 1 OAS LP12 9 10 24 x 1 2 Type F Screw 304 SS not shown 4 10759 10 Key Valve 1 BVL2S 11 12 Inch Chrome Key 1 KEY PC 12 12 Chrome Cover Plate 1 CVR BVL2CP 13 NPT Male to Male Flare Fitting 1 U1 8D S 14 NPT Female to Male Flare Fitting 1 U3 8D S Item Description Qty Part Number MT REPLACEMENT PARTS 1 The fire pit should be inspected and cleaned before initial use at least...

Page 11: ...ig 10 or 11 A 90 elbow is not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas leaks before presuming normal operation after conversion is complete CAUTION Ensure there is ventilation under the burner to provide fresh air for air shutter orifice Burner Pan GAS FLOW x 5 inch Nipple 113SS4 D5 OAS LP Orifice Flared Fitting U3 8...

Page 12: ...rainage for water and proper ventilation to dry out ACCESSORIES The following accessories are available from your local Firegear dealer distributor Each accessory comes with a separate installation manual Read each instruction thoroughly before installing Stainless Round Lid for 19 33 Pits Models LID 19R2 LID 25R2 LID 29R2 LID 33R2 Stainless Square Lid for 20 38 Pits Models LID 20S LID 26S LID 32S...

Page 13: ... S U1 8D S Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 14: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Page 15: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Page 16: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 17: ... units Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 14520 ...

Page 18: ... Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us when...

Reviews: