REV. C Page 10
MT Burning Spur Fire Pits
1
19-inch Round Stainless Pan
1
PAN-SS19R
1
25-inch Round Stainless Pan
1
PAN-SS25R
1
29-inch Round Stainless Pan
1
PAN-GV29R
1
33-inch Round Stainless Pan
1
PAN-GV33R
2
20-inch Square Stainless Pan
1
PAN-SS20S
2
26-inch Square Stainless Pan
1
PAN-SS26S
2
32-inch Square Stainless Pan
1
PAN-SS32S
2
38-inch Square Stainless Pan
1
PAN-SS38S
3
16-inch Spur Burner (used on 19” & 20” Pans)
1
B-Spur16
3
22-inch Spur Burner (used on 25”, 26”, 29”, Pans)
1
B-Spur22
3
31-inch Spur Burner (used on 32” & 33” Pans)
1
B-Spur31
3
36-inch Spur Burner (used on 38” Pan)
1
B-Spur36
4
5½” x 3” MT Cover Plate
1
PLATE-MT
5
1/2” NPS Brass Nut
1
105-8
6
⅞” Flat Washer/Spacer
1
ST3-113-1026
7
½” Flex Gas Line (46-inch Length)
1
T200-9898-46
8
Air Shutter Orifice Natural Gas (75,000 Btu’s)
1
OAS-NG29
8
Air Shutter Orifice Natural Gas (125,000 Btu’s)
1
OAS-NG16
8
Air Shutter Orifice Natural Gas (175,000 Btu’s)
1
OAS-NG05
8
Air Shutter Orifice Natural Gas (250,000 Btu’s)
1
OAS-NG25-64
8a Air Shutter Orifice Propane Gas (75,000 Btu’s)
1
OAS-LP41
8a Air Shutter Orifice Propane Gas (125,000 Btu’s)
1
OAS-LP31
8a Air Shutter Orifice Propane Gas (175,000 Btu’s)
1
OAS-LP26
8a Air Shutter Orifice Propane Gas (250,000 Btu’s)
1
OAS-LP12
9
10-24 x 1/2” Type F Screw, 304 SS (not shown)
4
10759
10 Key Valve
1
BVL2S
11 12 Inch Chrome Key
1
KEY-PC-12
12 Chrome Cover Plate
1
CVR-BVL2CP
13 ½” NPT Male to ½” Male Flare Fitting
1
U1-8D-S
14 ½” NPT Female to Male Flare Fitting
1
U3-8D-S
Item
Description
Qty.
Part Number
MT REPLACEMENT PARTS
1. The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.
2. Any component that is found faulty must be replaced with an approved component.
3. Any tampering or modifying with the fire pit is dangerous and voids all warranties.
4. During winter months in cold climates and various seasons operation the fire pit may be affected by weather
conditions. It is recommended to use a ventilated cover overtop of your fire pit to protect it from humid/rainy weather
conditions when not in use. Heavy rains/downpours could affect the fire pit operation if not covered; if this occurs
ensure you allow the fire pit time to dry out before attempting to operate.
NOTE
: If a combustible type cover is used
over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.
5. Over time stainless steel parts can discolor when heated, usually a golden or brown hue. This discoloration is normal
and does not affect the performance of the appliance.
FIRE PIT MAINTENANCE