FIP FLS M9.07 Instruction Manual Download Page 1

1

FLS M9.07

DUAL-PARAMETER 

CONDUCTIVITY AND 

FLOW MONITOR & TRANSMITTER

SAFETY INSTRUCTIONS

PACKING LIST

General Statements

• Do not install and service the product without following the Instruction 

Manual.

• This item is designed to be connected to other instruments which can be 

hazardous if used improperly. Read and follow all associated instrument 

manuals before using with it.

• Product installation and wiring connections should only be performed by 

qualified staff.

• Do not modify product construction.

Installation and Commissioning Statements

 

• Remove power to the instrument before wiring input and output connections.

• Do not exceed maximum specifications using the instrument.

• To clean the unit, use only chemical compatible products.

Please verify that the product is complete and without any damage. 

The following items must be included:

• M9.07 Dual-Parameter Conductivity and Flow Monitor & Transmitter

• Instruction Manual for M9.07 Dual-Parameter Conductivity and Flow Monitor 

& Transmitter

Summary of Contents for FLS M9.07

Page 1: ...ation and wiring connections should only be performed by qualified staff Do not modify product construction Installation and Commissioning Statements Remove power to the instrument before wiring input and output connections Do not exceed maximum specifications using the instrument To clean the unit use only chemical compatible products Please verify that the product is complete and without any dam...

Page 2: ...ny process to be controlled F3 00 F3 20 F6 30 F3 10 F3 05 F6 60 F6 61 F111 M9 07 X X X X X X ULF F3 80 pH ORP200 pH ORP400 pH ORP600 pH ORP800 C150 200 C100 C300 C6 30 M9 07 X X X X TECHNICAL DATA General Associated sensors FLS conductivity sensors FLS hall effect flow sensors or FLS F6 60 flow magmeters Materials case ABS display window PC panel wall gasket silicone rubber keypad 5 button silicon...

Page 3: ... 50 mA MAX sink 24 VDC MAX pull up voltage max pulse min 300 hysteresis user selectable 2 x Relay output Flow user selectable as MIN alarm MAX alarm Pulse Out Window alarm Off Conductivity user selectable as ON OFF Proportional frequency output MIN alarm MAX alarm Timed Pulse Off mechanical SPDT contact expected mechanical life min operations 107 expected electrical life min operations 105 N O N C...

Page 4: ...l or wall installation The panel version is installed using the panel mounting kit M9 SN1 while the wall mounting version is got fixing the panel mounting version on the wall mounting kit M9 KWX The mounting kits can be ordered directly connected to the monitor or separately and then simply installed on it PANEL MOUNTING WALL MOUNTING INSTALLATION ...

Page 5: ...ils M9 SN1 Wall installation Use the panel mounting kit M9 SN1 to fix the M9 07 on the dedicated frontal cutout of the wall mounting kit M9 KWX Tighten front screws of box and waterproof connectors of cables internally mount caps on screw sites to get a IP65 watertight installation ...

Page 6: ...upper part of the terminals for an easy cabling Insert wire tip or ferrule completely into the terminal and fix with the screw until finger tight Do not route the sensor DC power or 4 20mA cables in conduit containing AC power wiring Electrical noise may interfere with sensor signal Routing the sensor cable in grounded metal conduit can help prevent electrical noise and mechanical damage Wall Inst...

Page 7: ...VDC 4 20 mA Input 2 PLC Terminals 4 20 mA Input 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP 1 21 22 23 24 Power Supply 12 24 VDC 12 24 VDC PLC 4 20 mA Input 2 4 20 mA Input 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP 1 21 22 23 24 Power Supply 12 24 VDC 12 24 VDC PLC 4 20 mA Input 2 4 20 mA Input 1 V 2 1 L L L L 21 22 23 24 r Supply 4 VDC 4 VDC PLC 0 mA ut 2 0 mA ut 1 VDC VDC 2 1 LOOP 2 LOOP 1 LOOP 2 LOOP...

Page 8: ...12 24 VDC PLC Instrument Digital INPUT Digital INPUT Imax 50mA lmax 50mA lmax 50mA PLC DIGITAL INPUT N DIGITAL INPUT 2 DIGITAL INPUT 1 REF PLC N O Imax 50 mA Imax COM 3 4 lmax 50mA lmax 50mA Pt100 Pt1000 two wires connection Pt100 Pt1000 no connection Pt100 Pt1000 three wires connection 28 27 29 30 PT100 1000 27 28 29 30 PT100 1000 28 27 29 30 PT100 1000 USB PORT A USB port type B is available on ...

Page 9: ... 12 24 VAC VDC Imax 50 mA Imax Imax V V lmax 50mA HOLD HOLD 18 17 19 20 REED REED 12 24 VDC OPERATIONAL OVERVIEW The M9 07 Dual Parameter Conductivity and Flow Monitor Transmitter features a full graphic display and a five button keypad for system set up calibration and operation Full graphic display has a white backlight during standard conditions a green backlight in case a external device contr...

Page 10: ...d NTC not temperature compensation ATC automatic temperature compensation VIEW LEVEL MENU DIRECTORY conductivity temperature Output Settings item code software release conductivity temperature flow conductivity flow conductivity or temperature or flow analog output 1 conductivity or temperature or flow analog output 2 conductivity direct access to calibration flow infinte totalizer resettable tota...

Page 11: ...mal Point Measurement Decimal Point Flow Default Data Outputs 1 SSR 2 SSR 3 RELAY 4 RELAY Output Test 4 20mA1 4 20mA2 Flow Calibration Correction Factor Auto Calibration Calibration Conductivity Probe Calibration Temperature Probe Calibration Flow Settings K Factor Volume Unit Flow Unit Settings Conductivity Unit Temperature Unit Temperature Compensation Factor Cell Constant Temperature Compensati...

Page 12: ... type of failure a reference number correlated to the involved digital output is reported by the out put number PROCEDURE FOR OUTPUTS SETTING go to the Options menu enter into the Outputs activation sub menu enable output s go to the Outputs menu set the operating mode for each enabled output Monitor without digital output activated In case a digital output is enabled a icon will appear In case a ...

Page 13: ...nt Output relaxed Output energized Cond Time Set Point I His Set Point I Prop Band Relay Prop Cond Set Point I His Set Point I Cond Relay Timed Endpoint 100 pulses from 0 to max pulses min Starting point 0 pulses 5 10 Set Point I His Set Point I Prop Band Relay Prop Cond Set Point I His Cond Set Point I Relay Timed Hysteresis Setpoint Output relaxed Output energized Cond Time Digital outputs can b...

Page 14: ...X Cond Time Hysteresis Output relaxed Output energized Setpoint SOFTWARE UPDATING In order to update the Instrument Software with a New Firmware Release follow the suggested procedures TO UPDATE INSTALLED UNITS Download the interface software FLS Calibration System and the Updated Software on www flsnet it Launch the software FLS Calibration System on the laptop Select OPTION and then UPGRADE FIRM...

Page 15: ...l panel mount monitors M9 KUSB USB cable for device interfacing USB cable dedicated to FLS products 1 5 meter long Part No Name Description M9 SN1 Fixing snails 2 fixing snails for panel installation of FLS monitors NOTE At the end of the procedure restart the instruments in order to refresh M9 07 software It takes 90 seconds to refresh the SW Please do not interrupt the restarting process TO UPDA...

Page 16: ...FIP Formatura Iniezione Polimeri S p A Loc Pian di Parata 16015 Casella Genova Italy Tel 39 010 96211 Fax 39 010 9621209 www flsnet it I2372 IMM907E REV 01 10 2016 ...

Reviews: