background image

PB

1

COOK TOP

INSTALLATION 

AND

OPERATING

INSTRUCTIONS

FI310/FI320/

FI640/FI850/FI950

Summary of Contents for FI310

Page 1: ...1 COOK TOP INSTALLATION AND OPERATING INSTRUCTIONS FI310 FI320 FI640 FI850 FI950 ...

Page 2: ...er its service agent or a similarly qualified person to avoid a hazard Any modifications that may be required to the electrical system for the installation of the range hood must only be made by qualified electricians 3 Be sure to SHUT OFF MAIN BREAKER PANEL before servicing the cook top 4 Use your Fiore cook top only for its intended purpose The manufacturer disclaims all liability for any other ...

Page 3: ...l codes with the National Fuel Gas Code ANSI Z223 1 NFPA54 Latest Edition ANSI Z223 1 NFPA Be sure your cooktop is installed properly by a qualified installer or service technician To eliminate reaching over surface burners cabinet storage above burner should be avoided Do not install the unit near an outside door or where a draft may affect its use This product must be installed by a licensed plu...

Page 4: ...e the electrician show you where your main cooktop disconnect is located Check with your local utilities for electrical codes which apply in your area Failure to wire your cooktop according to governing codes could result in a hazardous condition If there are no codes your cooktop must be wired and fused to meet the requirements of the National Electrical Code ANSI NFPA No 70 Latest Edition You ca...

Page 5: ...S TABLE OF CONTENTS INSTALLATION PREPARATION 06 DIMENSIONS AND CLEARANCES 09 POWER SUPPLY LOCATIONS 10 INSTALLATION INSTRUCTIONS 12 INSTALL PRESSURE REGULATOR 13 ASSEMBLE BURNERS AND CHECK IGNITION 14 LP GAS CONVERSION 16 SETTING THE MINIMUM FLAME 20 ...

Page 6: ...to order the correct model for the installation situation PARTS INCLUDED 2 Screws Regulator 2 Hold Down Brackets MATERIALS YOU MAY NEED Joint Sealant Pipe Fittings Shut Off Valve CSA Approved Flexible Gas Line 1 2 Min ID 1 2 NPT Connection 3 foot Maximum Length Massachusetts Only NOTE Purchase new line do not use previously used flexible gas line TOOLS YOU WILL NEED FOR INSTALLATION Pencil Phillip...

Page 7: ...k of burns caused by reaching over heated surface units Working areas adjacent to the cooktop should have 18 minimum clearance between countertop and cabinet bot tom A 36 or wider exhaust hood with 350 CFM or greater airflow rating is recommended for use over this Mono gram cooktop Installation must complied with local codes In the absence of local codes the gas cooktop must complied with the Nati...

Page 8: ...terature package and read them carefully before you begin Be sure to place all literature Owner s Manual Installations etc in a safe place for future reference 4 Make sure you have all the tools and materials you need before starting the installation of the cooktop 5 Your home must provide adequate electrical service tools to ensure your safety and to maintain your cooktop as well Refer to section...

Page 9: ...to the cooktop regulator The liquid propane model is designed to operate at 10 water column pressure A regulator is required at the LP Gas source to provide a minimum of 11 water column to the cooktop regulator For ease of installation if local codes permit the gas supply line into the cooktop should be 1 2 or 3 4 ID flexible metal appliance connector with three to five feet long NOTE Purchase new...

Page 10: ...te the connection between the regulator and the shut off valve Before testing for leaks make sure all burner knobs are in the OFF position After connecting the cooktop to gas check system for leakage with a manometer If a manometer is not available turn the gas supply on to the cooktop and use a liquid leak detector at all joints and connections to check for leak ing Tighten all connections if nec...

Page 11: ...ORTANT Please read carefully FOR PERSON SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance The customer should have the wall receptacle and circuit checked by a qualified electrician to...

Page 12: ...ENSIONS AND CLEARANCES Observe all minimum clearances FI310 Series Clearances FI640 Series Clearances FI850 950 Series Clearances 22 5 9 2 9 5 1 9 2 9 60cmcuttingout 7 5 150 4 9 0 560 28 74 5 9 1 9 2 9 2 9 5 80 and 90cm cutting out 7 5 150 730 4 9 0 5 9 11 2 9 5 1 9 2 9 30cmcuttingout 7 5 150 4 9 0 280 DIMENSIONS AND CLEARANCES Observe all minimum clearances FI310 Series Clearances FI640 Series Cl...

Page 13: ...s and screws see Figure D FIGURE D INSTALLATION INSTRUCTI FIGURE B FIGURE A FIGURE C FIGURE D ONS 1 INSTALL THE COOKTOP A Remove the screws on the sides of the cooktop burner box Use those screws to attach the side mounting brackets B Insert the cooktop centered into the cutout opening Make sure the front edge of the countertop is parallel to the cooktop Check clearances at the front back and side...

Page 14: ...s on the burner heads Make sure that the burner caps are properly seated on the burner heads Burner cap properly seated Burner cap not properly seated Check igniters Operation of the electric igniters should be tested after the cooktop and supply line have been carefully checked for leaks and the cooktop has been connected to the electrical power Push and turn a burner valve to the LITE position A...

Page 15: ...g again Turn on each burner On LP models flames should be blue in color but may have yellow tips Natural gas models should have soft blue flames The burner flames should not flutter or blow away from the burner The flame should be no less than 1 4 on the lowest setting and no greater than 1 1 2 on highest setting Burners should be checked frequently WARNING If you attempt to measure the flame plea...

Page 16: ...converted for Liquid Petroleum LP Gas the LP gas supply is required to provide a minimum of 10 to a maximum of 14 water column to the range regulator CAUTION The cooktop as shipped from the factory is set for use with its intended gas If you wish to use your cooktop with the alternate gas you must first replace the orifices and convert the pressure regulator WARNING This conversion must be perform...

Page 17: ... A FIGURE b For Natural Gas usage the retainer pin will look like this See Figure B FIGURE D Unscrew the cap with a Crescent wrench See Figure A Remove the retainer pin See Figure C Proceed toreverse the retainer pin and place itback into the regu lator cap This ishow the regulator pin looks for LP gas usage See Figure D FIGURE E 5 Screw the regulator cap back into the regulator and re at tach the...

Page 18: ... screw removed previously 5 Replace the burner bases heads caps and top grates A A F T 5 F I R L A A F T 5 F BURNER I R L 18 19 2 CHANGE bURNER NOZZLES INSTALLATION TIP First remove all nozzles and then start replacing them This will help to prevent the possi bility that some may not be replaced A Remove the burner grates burner caps and burner heads B Using a 7mm nut driver remove the top burner ...

Page 19: ...xact locations as noted in the illustrations above and the table below Replace the burner bases heads caps and top grates Confirm burner caps are properly resting on the burner head LIQUID PRETROLEUM LP GAS NOZZLES NOZZLES 56 56 56 80 89 70 80 56 56 BURNER POSITION NOZZLE DIAMETER MINIMUM PRESSURE MAXIMUM PRESSURE RATE BTU H Auxiliary Front Right 1 x 0 70 10 14 4 800 Semi Rapid Rear Left Right 1 x...

Page 20: ...ulation obtained is sufficient to maintain heating of the ther mocouple If it is not increase the minimum SETTING THE MINIMUM FLAME The flame on the small output is regulated by the factory When the injectors have been replaced or there are special mains pressure conditions it may be necessary to regulate the minimum flame again The operations necessary to set the minimum flame are as following Li...

Page 21: ...21 al et The w the ...

Page 22: ...ber Date and Location of Purchase Scanned Copy of the Original Sales Receipt Within the warranty time period a defective product will receive free repair or replacement if repair is unavaila ble Repair must be performed by an authorized Fiore service technician The warranties provided in this statement are not transferable and have validity from the date of purchase IMPORTANT Immediately upon rece...

Page 23: ...ident alteration misuse abuse improper installation Damage to or failure of the product resulting from accident abuse misuse or use for other than its intended purpose caused by the use of detergents cleaners chemicals or utensils other than those recommended in all instructions supplied with the product Defects and damages arising from transportation of the product to the home of the owner and ot...

Page 24: ...24 TM The appliances are for household use only ...

Reviews: