background image

 

 

Smoke

 

detector

 

 

 

Datasheet

 

CALYPSO

II

 

Smoke detector 

 

 

 

Summary of Contents for CALYPSO-II

Page 1: ...Smoke detector Datasheet CALYPSO II Smoke detector ...

Page 2: ... GENERAL CHARACTERISTICS supply lithium battery non replaceable autonomy 10 years smoke detection by light diffusion sound power 85dB at 9 and 10 battery light and sound signal in case of default battery test frequency automatic about every 50 seconds mounting screws and rawplugs supplied for unperforated material protection against false alarm protection grid against insects with algorithm handle...

Page 3: ...cur garage kitchen see Implementation precaution Avoid installing detectors in the bathroom Examples minimal protection advice optimal protection implementation precaution Flat House To install a detector in the garage or the kitchen please see Implementation precaution INSTALLATION ON THE CEILING OR ON THE WALL Example Respect the minimal distances indicated below Long corridor In more than 10 me...

Page 4: ...and of a rapid clogging of the detector Respect a minimum distance of 2 meters for a minimum 9m surface from any device generating smoke or vapour Below 9m installing a detector in the kitchen is banned Use the neutralization device whenever you use a device generating smoke or vapour Example INSTALL AND COMMISSION ONE DETECTOR Necessary tools and pre requisite Drilling machine bit 4mm screws and ...

Page 5: ...ng it towards you After 20 seconds the detector is commissioned see below on the left 2 Put the key away in the location space provided see below on the right At the end of life of the detector you can disconnect the battery using the tab to stop the default sound signal and avoid any electric risk when recycling see Closure of the detector Mounting the detector 1 Present the detector on its base ...

Page 6: ...tton for 2 sec After the test sound signal 3 short beeps can be heard This confirm the neutralization Put a neutralized detector back in commissioning You can cancel the neutralization before the 10 minutes 1 Neutralized detector 1 red flash every 7 sec in presence of smoke 2 Press the test button 2 short beeps indicates that the neutralization has been taken into account 3 Detector is back to sta...

Page 7: ...h 1 long beep 50 sec battery default main power supply see instructions above TEST With the test button We recommended to test the functionning of the detector once a week Briefly push the test button less than 2 sec The test button flashes red and emits a sound signal Use this test as a chance to acquaint your children with the alarm signal and to explain them what to do if a fire occurs in your ...

Page 8: ... CEE directive relative to construction products NF mark The NF mark affixed on this product guarantees constant safety and quality controlled by specialists With its strict and exhaustive controls owner quality management system manufacturing controls audit monitoring tests it brings the consumer all guarantees of compliance to certified products The NF DAAF mark complies with the certification r...

Reviews: