coupling matches up with the plastic insert and seats properly. Make sure 

rabbet on the motor is firmly seated into the motor adapter.

 

  

CAUTION:  Pump assembly may be top heavy.

5.  Rotate the pump discharge and mounting plate (if ordered) to the de-

sired orientation. Align the holes in the mounting plate and the motor 
adapter with the holes in the motor face. Secure the mounting plate 
and motor adapter to the motor using (4) washers, lock washers, and 
3/8” bolts (items 6,7,8) from the hardware package.

6.  Ensure that lock rings are securely snapped in place and did not loosen 

during shipment.

7.  Install the pump into the system according to the installation instruc-

tions provided.

FOR 56C FRAME VKC8 [54”-60”(137-152 cm)] AND ALL 

VKC10 PUMP ADAPTERS WITH FLYWHEELS (ITEM 35 IN 

FIGURE 8):

1.  Unpack the pump and any supplied accessories and examine for dam-

age.  If damage is detected, save the packaging and notify the carrier 
immediately.

2.  Prepare to assemble the pump onto the motor by placing the motor 

on the fan cover on a suitable clean, level work surface.

3.  Install motor key into motor shaft key slot. Align the keyway slot on 

the flywheel (item 35 in figure 8) and slide the flywheel onto the motor 
shaft with the protruding boss towards the motor face. Align the keyway 
slot in the coupling half and slide the coupling half on. Set coupling 
half with the motor shaft recessed 7/32” and tighten both setscrews 
with a 1/8” Allen wrench to 70 in-lbs.

4.  Slide the flywheel forward so that it rests against the backside  

 

 of the coupling half. Tighten both setscrews.

5.  Insert the coupling insert (yellow internally splined plastic sleeve) into 

the coupling half on the motor shaft. Place coupling support (item 
38A in figure 8) into center of coupling half with the short side facing 
the motor. Carefully slide the motor adapter end (item 9 in figure 8) 
of the pump assembly over the motor shaft until both coupling halves 
are completely seated in the coupling insert. Make sure rabbet on the 
motor is firmly seated into the motor adapter.

 

     CAUTION: Pump assembly may be top heavy

6.  Rotate the pump discharge and mounting plate (if ordered) to the 

desired orientation. Align the holes in the mounting plate and the 
motor adapter with the holes in the motor face. Secure the mounting  
 plate and motor adapter to the motor using (4) washers, lock washers 
and 3/8” bolts (items 6, 7, 8) from the hardware package. 

7.  Ensure that lock rings are securely snapped in place and did not loosen 

during shipment.

8.  Install the pump into the system according to the installation    

  instructions provided.

ASSEMBLY

WARNING: Magnetic field hazard. This pump contains powerful  
rare earth magnets. When the pump is disassembled (not 
connected to a motor) and the magnets are exposed, these 
magnets produce powerful magnetic fields. Individuals with 
cardiac pacemakers, implanted defibrillators, other electronic 
medical devices, metallic prosthetic heart valves, internal wound 
clips (from surgery), metallic prosthetic devices or sickl cell 
anemia  must not handle or be in the proximity of the magnets 
contained inside the pump. Consult a health care provider for 
specific recommendations before working with this pump.

PUMPS WITH MOTORS

1.  No assembly required.  Simply unpack the pump and motor and ex-

amine for any signs of shipping damage.  If damage is detected, save 
the packaging and notify the carrier immediately.

2.   Ensure that lock rings are securely snapped in place and did not loosen 

during shipment.

3.   To install the pump into the system, follow the installation instructions 

provided.

PUMPS WITHOUT MOTORS 

Note

:  Finish Thompson has added extra weight (Flywheel item 35 in 

Figure 8) to several of our VKC Series Pumps to slow down motor start 
up & prevent possible magnet decoupling. It is necessary to know 
whether your pump was supplied with the flywheel. Flywheels are sup-
plied with all VKC8 (54”- 60”) & All VKC10 pumps both 56C NEMA & 80 
Metric frame motor adapters. If you are unsure whether your pump was 
supplied with a flywheel please contact our Tech Service Department at 
PH: 800-888-3743 or email  [email protected]

Note:

 motor assembly videos are available on line at http://www.Fin-

ishthompson.Com/downloads/maintenance-videos/

FOR 56C FRAME VKC5.5,6,6H, 7 AND 8 PUMP ADAPTERS 

WITHOUT FLYWHEELS [12” - 48” (30-122 cm)]. USE 
FIGURE 7.

1.  Unpack the pump and any supplied accessories and examine for dam-

age.  If damage is detected, save the packaging and notify the carrier 
immediately.

2.  Prepare to assemble the pump onto the motor by placing the motor 

on the fan cover on a suitable clean, level work surface.

3.  Slide the supplied coupling half  (metal half of item 27 in figure 7) 

onto the motor shaft with the splined side facing the pump. Adjust the 
coupling half so that the motor shaft is recessed 7/32” below the top 
of the coupling. Insert the motor shaft key in the slot and tighten both 
setscrews with a 1/8” Allen wrench to 70 in-lbs.

4.  Install the coupling insert (yellow internally splined plastic sleeve) onto 

the coupling half on the motor shaft. Carefully slide the motor adapter 
(item 9 in figure 7) onto the motor making sure the pump shaft.

Summary of Contents for VKC10 Series

Page 1: ...re that lock rings are securely snapped in place and did not loosen during shipment 8 Install the pump into the system according to the installation instructions provided ASSEMBLY WARNING Magnetic field hazard This pump contains powerful rare earth magnets When the pump is disassembled not connected to a motor and the magnets are exposed these magnets produce powerful magnetic fields Individuals w...

Page 2: ...mp shaft coupling matches up with the plastic insert and seats properly Make sure rabbet on the motor is firmly seated into the motor adapter 6 Rotate the pump discharge and the mounting plate if ordered to the desired orientation Align the bolt holes on the mounting plate with the motor adapter item 9 and the metric motor adapter flange item 2 Secure with the hardware provided CAUTION Pump assemb...

Page 3: ...void mix up during reassembly EXAMINATION 1 Check the impeller drive bushing item 17 thrust ring item 20 ce ramic thrust ring and shaft for cracks chips scoring or excess wear See figure 2 Replace as required 2 Check for loose magnets on the drive assembly or rubbed areas on the impeller or column housing adapter assemblies Contact your distributor or FTI Technical Service if a problem is found su...

Page 4: ...xtension item 30 by aligning the threaded end of the shaft through the bearing and sliding it down to the top of the motor adapter Secure the motor and mounting plate to the table Using a strap wrench thread the column extension onto the motor adapter Tighten the section until there is no gap between the sections and the flats are parallel Tighten the two bearing setscrews 3 When you are down to t...

Page 5: ...by hand to verify nothing is rubbing or binding Reinstall the pump into the system according to the installation instructions GENERAL NOTES 1 Do not pump liquids containing metal fines 2 If magnets decouple stop the pump immediately The rare earth magnets used in this pump are more resistant to demagnetization but operating the pump with the magnets decoupled will eventually weaken the magnets 3 P...

Page 6: ...6 VKC SERIES WITHOUT FLYWHEEL VKC5 5 6 6H 7 and 8 12 48 30 cm 122 cm 56C 63 71 and 80 Frames Figure 7 ...

Page 7: ...7 VKC SERIES WITH FLYWHEEL VKC8 54 60 137 cm 152 cm All VKC10 56C and 80 Frames Figure 8 ...

Page 8: ...dels A103377 1 PVDF 18 to 60 length models M101981 2 PVDF 12 length models A103377 2 10 1 PVC Mounting Plate 9 1 2 x 14 3 4 Optional VKC 5 5 6 6H 105612 VKC 7 8 10 105611 11 Lock Ring Polypropylene M101984 1 PVDF M101984 2 12A Motor Adapter Column O Ring FKM 4 mm J103306 EPDM 4 mm J103308 12B Motor Adapter Column O Ring FKM 4 5 mm J103307 EPDM 4 5 mm J103309 13 1 Drive Shaft 12 56C frame M102119 9...

Page 9: ...ceramic bushing A102746 23 10 pole polypropylene with carbon bushing A102746 7 10 pole polypropylene with PTFE bushing A102746 12 10 pole polypropylene with ceramic bushing A102746 24 10 pole PVDF with carbon bushing A102746 8 10 pole PVDF with PTFE bushing A102746 15 10 pole PVDF with ceramic bushing A102746 25 12 pole polypropylene with carbon bushing A102746 16 12 pole polypropylene with PTFE b...

Page 10: ...ng Not Shown VKC 5 5 6 6H 1 x 3 4 polypropylene J103158 VKC 5 5 6 6H 1 x 3 4 PVDF J103153 VKC7 8 10 1 1 2 x 1 polypropylene J103160 VKC7 8 10 1 1 2 x 1 PVDF J103159 25 1 Elbow Not Shown VKC5 5 6 6H polypropylene 90 x 1 J103167 VKC5 5 6 6H PVDF 90 x 1 J103168 VKC7 8 10 polypropylene 90 x 1 1 2 J103165 VKC7 8 10 PVDF 90 x 1 1 2 J103166 26 1 Optional Discharge Piping Not Shown Available in polypropyl...

Page 11: ...alth and safety requirements as specified by the EU Directives listed The product may not be taken into service until it has been established that the drive motor for the centrifugal pump complies with the provisions of all relevant EU Directives The complete product complies with the provisions of the EC Directive on machinery safety provided motors carry CE marking This declaration is valid prov...

Page 12: ...duct damage or personal injuries sustained when the product is modified in any way If this warranty does not apply the purchaser shall bear all cost for labor material and transportation Manufacturer shall not be liable for incidental or consequential dam ages including but not limited to process down time transportation costs costs associated with replacement or substitution products labor costs ...

Reviews: