background image

EF SERIES PUMPS

EFP, EFS, & EFV

OPERATION & PARTS MANUAL

P/N 107317 R12

Summary of Contents for EF Series

Page 1: ...EF SERIES PUMPS EFP EFS EFV OPERATION PARTS MANUAL P N 107317 R12 ...

Page 2: ...ation is valid provided that the devices are fully assembled and no modifications are made to these devices Type of Device Drum and Container Pump Tubes and Accessories Models EU Directives Machinery Safety 2006 42 EC Applied Harmonized Standards EN ISO 12100 EN 809 Manufacturer Finish Thompson Inc 921 Greengarden Road Erie Pennsylvania 16501 1591 U S A Signed _ President 3 April 2020 Person s Aut...

Page 3: ...ble for any damages to people or property In case of doubt or enquiries please reply to our Technical Service department directly at the following address Finish Thompson Inc 921 Greengarden Rd Erie PA 16501 U S A Tel 1 814 455 4478 Fax 1 814 455 8518 www finishthompson com fti finishthompson com Index Introduction Pump Specifications 3 Warranty General Terms Conditions 4 Safety 5 Important Safety...

Page 4: ...sembling with new or repaired parts free of charge delivered by Finish Thompson Inc Parts subjected to normal wear and tear shall not be covered by the warranty Finish Thompson Inc shall decide as to whether the defective or faulty part shall be replaced or repaired Transportation charges are prepaid to Finish Thompson 4 The warranty of the products shall be valid for a period of 12 months from th...

Page 5: ... ground and the tanks containers are separately bonded to ground ALWAYS inspect the integrity of the ground wire connections prior to each use NEVER leave the pump unattended while in use NEVER run the pump dry without fluid NEVER run the pump with a closed valve deadhead for longer than 1 minute ALWAYS use and store the pump and motor in an upright position NEVER use in pressurized containers ALW...

Page 6: ... dommages matéri els ou corporels causés par une utilisation inappropriée de l équipement AVERTISSEMENT Il est de la responsabilité de l utilisateur de faire fonctionner la pompe conformément aux règles OSHA Santé et Sécurité au Travail relatives à la distribution de liquides Les conteneurs de pompes doivent être électriquement mis à la terre lors de l utilisation de liquides inflammables ou combu...

Page 7: ... Gravity 1 6 1 6 1 6 Max Viscosity 300 cP 300 cP 300 cP Min Max Fluid Temperature 0 F Min to 150 F Max 0 F Min to 160 F Max 0 F Min to 212 F Max 18 C Min to 66 C Max 18 C Min to 71 C Max 18 C Min to 100 C Max Wetted Materials Polypropylene FKM PTFE ETFE 316 SS Pure Polypropylene PVDF FKM PTFE ETFE Alloy 625 316 SS FKM optional PTFE seal EPDM Perlast o rings PTFE ETFE EFV 54 Maximum Temperature 150...

Page 8: ...perly secured before operating the motor torque Finish Thompson hose clamps to 25 in lbs 2 8 N m 4 Begin pumping by turning the motor on and verifying that there are no leaks If leaks are noticed immediately turn the motor off and check all discharge hose connections NEVER allow the pump to run dry NEVER pump liquids containing solids that can damage internal pump parts i e metal chips Pumping sol...

Page 9: ...the inner tube and center support items 13 14 4 Inner Tube Center Support Removal To remove the inner tube and center sup port turn the inner tube to unseat the o rings item 12 and then pull the inner tube away from the head 5 Shaft Sleeve Removal The shaft sleeve item 15 will drop out of the inner tube by holding it in a vertical position and turning 6 Center Support Removal 40 and 48 lengths onl...

Page 10: ... half coupling counter clockwise right hand thread to verify that the bearing is seated properly See figure 7 Reinstall the half coupling 4 Inner Tube Center Support Shaft Sleeve Installation for all models Reinstall the inner tube center support if used and shaft sleeve items 13 14 15 Slide the shaft sleeve onto the shaft The shaft sleeve is self positioning so slide it up as far as it will go on...

Page 11: ...user into the outer tube item 16 turning counter clockwise left hand thread Figure 9 Figure 10 Figure 11 7 Thread the diffuser item 17 completely onto the bottom of the outer tube item 16 Hand tighten Thread the impeller onto the shaft by hand While holding the half coupling with the other hand turn the impeller clockwise right hand thread See figure 11 Install the diffuser cover item 19 onto the ...

Page 12: ...12 EFP EFV SERIES PUMP EXPLODED VIEW 1 2 3 4 5 6 7 8 9 10 11 16 12 13 14 15 17 18 19 ...

Page 13: ...13 EFS SERIES PUMP EXPLODED VIEW ...

Page 14: ...154 N A 10 1 SPOUT POLYPROPYLENE 107072 1 N A N A PVDF N A 107072 2 N A 11 1 NUT POLYPROPYLENE 107069 1 N A N A PVDF N A 107069 2 N A 12 2 INNER TUBE O RING FKM STANDARD 107299 107299 107299 EPDM 107729 107729 107729 PERLAST N A N A 110001 13 1 INNER TUBE 16 107294 1 107294 1 107578 1 27 107294 2 107294 2 107578 2 40 107294 3 107294 3 107578 3 48 107294 4 107294 4 107578 4 54 107294 5 107294 5 N A...

Page 15: ...067 1 N A N A TEFZEL ETFE N A 107067 2 107067 2 19 1 DIFFUSER COVER 110080 1 110080 2 107584 20 1 DIFFUSER BUSHING ONLY PTFE N A N A 107585 21 2 DIFFUSER O RING FKM STANDARD N A N A 107586 EPDM N A N A 107766 PERLAST N A N A 110002 22 1 GROUNDING SCREW BRASS N A N A J100822 23 1 GROUNDING SCREW LOCKWASHER BRASS N A N A J100823 N A Not Applicable Item 20 is included in the diffuser item 17 Diffuser...

Page 16: ...Service 1 800 888 3743 P N 107317 Rev 12 4 3 2020 ...

Reviews: