![finetech FINEPLACER lambda Operator'S Manual Download Page 29](http://html1.mh-extra.com/html/finetech/fineplacer-lambda/fineplacer-lambda_operators-manual_2289605029.webp)
FINEPLACER
®
lambda
Rev-Nr. 1.1
29
•
If available, connect the vacuum pipette (24) to the VACUUM PICKUP socket
(61), at the front of the Placer Control Box (39).
•
First connect the power cord with the Placer Control Box socket (62f) and
then into the appropriate AC power source. Make sure that LED LINE (151) is
'ON'. Switch the Placer Control Box (39) to "I" 'ON'), pressing the POWER
switch (57); LED (58) should now be ON.
•
Connect the fiber optic illumination light control boxes to the Placer Control
Box's rear 3-pole output socket using the cable supplied. Further custom
specified lighting methods are possible.
4.1.5
Preliminary Settings and Checkout
•
Using the arm handle (11), rotate the pivot arm (27) to the vertical position
(Upper Arm Position, UAP).
•
Set the Placer Control Box (39) to "I" (ON) by pressing the POWER
switch (57).
•
Hold the positioning table by its X and Y micrometer screws (50 and 51) and
use them as handles. Press or release the foot switch (64) to determine that
the air cushion of the positioning table (39) is activated and can be moved
freely on the base plate (70) or is fixed in its position by the magnet.
•
When the foot switch is released, the positioning table lays directly on the
base plate without air cushion. It should be able to be rotated a few degrees
around the lambda's optical axis. Use the micrometer screws as handles to
achieve coarse
Θ
(Theta) correction. During this procedure, the positioning
table must not scrape the base plate.
•
An optional Target Finder (1) should project its red spot on the target area as
long as the foot switch is pressed and the optics slide is at its leftmost
position.
•
Check that the vacuum at the Placement Head (20) is strong enough to hold
all your components safely.
•
Check on the control box (39) that the relevant lighting control is able to dim
the lighting from maximum brightness to dark.
•
For general adjustment purposes refer to Chapter 4.2.
4.2
Adjusting the Placement Accuracy of the lambda
Before taking up work, you should read and understand the whole of part 3 and 2.2
of this handbook. We recommend you to get familiar with the logic of the vacuum
control (see 3.43). After this, please print out or make a copy of the instructions
below and take them to the machine. Follow each instruction thoroughly.