background image

Solar Inverter

TRIO-20.0/27.6-TL-OUTD

Quick Installation Guide

In addition to what is explained in this quick installation guide, the safety and installation information provided in the product manual must be read and 

followed. The technical documentation for the product is available at the website.

The device must be used in the manner described in the manual. If this is not the case the safety devices guaranteed by the inverter might be 

ineffective.

Summary of Contents for TRIO-20.0-TL-OUTD

Page 1: ...uide the safety and installation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective ...

Page 2: ... fit connectors String protection fuses AC DC disconnect switch CAR D CO M CAR D 10 16 14 17 22 09 15 12 13 18 19 S2X wiring box version Quick fit connectors String protection fuses DC overvoltage surge arresters AC overvoltage surge arresters AC DC disconnect switch Main components 09 Communication board 13 DC input terminal board 17 AC output terminal board 10 Service cable glands 14 AC DC disco...

Page 3: ...C circuit part b6 Warning b18 DC AC circuit part b7 Temperature derating b19 AC voltage value b8 Instantaneous power b20 AC current value b9 MPP scan running b21 Connection to the grid b10 Graphic display b22 Grid status b11 Power graph b23 Cyclic view on off b12 Total energy NOT available 5 Lifting and transport Transport and handling Transport of the equipment especially by road must be carried ...

Page 4: ...he bracket C into the slot of the A and tighten the screws using a spirit level to check it is horizontal Fit the bracket D into the slot of the A and tighten the screws using a spirit level to check it is horizontal Fasten the Wiring Box 02 inserting the head of the rear screws into the slots in the bracket remove the front cover and carry out all the necessary connections NOTE D The inverter doe...

Page 5: ...ovoltaic modules installed For string connections using the S2F S2X wiring box the quick fit connectors multicontact or weidmuller situated at the bottom of the mechanics are used For each input channel there are two groups of connectors Input connectors MPPT1 19 with codes 1A 1B 1C Input connectors MPPT2 20 with codes 2A 2B 2C Connect all the strings included in the design of the system and alway...

Page 6: ...H CARD COM CARD a05 1 2 0 1 2 3 4 5 6 7 8 9 A BC DE F 0 1 2 3 4 5 6 7 8 9 A BC DE F 0 1 2 3 4 5 6 7 8 9 A BCD E F 0 1 2 3 4 5 6 7 8 9 A BCD E F 1 2 1 3 CHINA 400V CHINA ENGLISH 1 4 KOREA 380V KOREA ENGLISH 1 5 TAIWAN 400V TAIWAN ENGLISH 1 6 CHECA REPUBLIC 400V CZECH CZECH 1 7 GERMANY VDE AR N 4105 400V GERMAN 1 8 CEI 021 400V EXT prot CEI021 EX ITALIAN 1 B SOUTH AFRICA 400V S AFRICA ENGLISH 1 C SP...

Page 7: ...ough the menu using the buttons of the LED panel 25 Section b10 consists of 2 lines with 16 characters per line Viewing of the GENERAL INFORMATION is cyclic This information relates to the input and output parameters and the inverter identification parameters By pressing ENTER it is possible to lock scrolling on a screen to be constantly displayed Press ESC to access the three main menus which hav...

Page 8: ...Output Power Pacmax 22000 W 3 30000 W 4 Maximum apparent Output Power Sacmax 22200 VA 30000 VA Maximum Output Current Iacmax 33 0 A 45 0 A Inrush Current Negligible Maximum output fault current 63Arms 100mS Rated Output Frequency fr 50 Hz 60 Hz Output Frequency Range fmin fmax 47 53 Hz 57 63 Hz 2 Nominal Power Factor Cosphiac r and adjustable range 0 995 adj 0 9 or fixed by display down to 0 8 wit...

Reviews: