![Fimer PVS-100-TL B2 Product Manual Download Page 13](http://html.mh-extra.com/html/fimer/pvs-100-tl-b2/pvs-100-tl-b2_product-manual_2289268013.webp)
EN
13
3. Characteristics
3.1 General conditions
A description of the equipment characteristics is provided to identify its main components and specify the technical terminology used in
the manual.
This chapter contains information about the models, details of the equipment, characteristics and technical data, overall dimensions and
equipment identification.
ATTENTION –
A
The customer/Installer takes full responsibility if, when reading this manual, the chronological order of its presentation
provided is not observed. All information is provided considering occasional inclusion of information in previous chapters.
3.2 Identification of equipment and manufacturer
FORBIDDEN –
J
The labels affixed to the equipment must NOT be removed, damaged, stained, hidden, etc., for any reason
whatsoever. Do NOT hide the labels by foreign objects and parts (rags, boxes, equipment, etc.); they must be regularly cleaned and
always kept in sight.
NOTE –
D
The technical data provided in this manual does not substitute the data supplied on the labels affixed to the equipment.
NOTE –
D
The labels shown below have to be intended as example only.
3.2.1 Regulatory label
MODEL:
MODEL
SOLAR INVERTER
Made in Italy
www.abb.com/solar
MODEL:
MODEL
POWER MODULE
(COMPONENT OF MODEL . . . . . . . . .)
PROTECTIVE CLASS: I
V
dc max
V
acr
f
r
P
acr (cos = ± 0.9)
φ
P
acr (cos = 1)
φ
I
dc max
I
sc max
I
ac max
S
max
IP66
IP54 Cooling
Section
DIN V VDE 0126-1-1
PROTECTIVE CLASS: I
-25 to + 60 °C
-13 to +140 °F
V
dc Operating Range
V
dc MPP
6 minutes
B
IP66
-25 to + 60 °C
-13 to +140 °F
MODEL:
MODEL
www.abb.com/solar
WIRING BOX
(COMPONENT OF MODEL . . . . . . . .)
B
Made in Italy
PROTECTIVE CLASS: I
ANATEL:00440-18-01459
MODEL:
MODEL
SOLAR INVERTER
Made in Italy
www.abb.com/solar
MODEL:
MODEL
POWER MODULE
(COMPONENT OF MODEL . . . . . . . . .)
PROTECTIVE CLASS: I
V
dc max
V
acr
f
r
P
acr (cos = ± 0.9)
φ
P
acr (cos = 1)
φ
I
dc max
I
sc max
I
ac max
S
max
IP66
IP54 Cooling
Section
DIN V VDE 0126-1-1
PROTECTIVE CLASS: I
-25 to + 60 °C
-13 to +140 °F
V
dc Operating Range
V
dc MPP
6 minutes
B
IP66
-25 to + 60 °C
-13 to +140 °F
MODEL:
MODEL
www.abb.com/solar
WIRING BOX
(COMPONENT OF MODEL . . . . . . . .)
B
Made in Italy
PROTECTIVE CLASS: I
ANATEL:00440-18-01459
Power module
A
A
L
E
PVS-100_120-TL_B2_S(X-Y)2
6A
6B
6C
6D
5A
5B
5C
5D
3A
3B
3C
3D
4A
4B
4C
4D
2A
2B
2C
2D
1A
1B
1C
1D
Wiring Box
L
A.
Power module/wiring box model
E.
Main technical data
L.
Certification marks
3.2.2 NRS097-2-1 label
WARNING!
NRS 097-2-1:2017 (South Africa)
It is not intended to connect this Inverter to a network with an higher
Network Impedance.
Reference Impedance
Fault Level
0.156
1475
Total [ Ω ]
I_SC [ A ]
3.9
1018
X/R ratio
S_SC [kVA] (three phase)
ATTENTION –
A
For connection to the network in South Africa. According to NRS097-2-1 requirements, at the end of installation it is
mandatory to apply the label at the left (supplied with the inverter) near the power module regulatory label.