background image

Page 1

 

 

www.fimcoindustries.com

 

1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD  57049      

Toll Free Phone: 800

-

831

-

0027 : Toll Free Fax: 800

-

494

-

0440

 

[5195697

   

 

 

 

 

 

(03/22)]

 

Model: LG

-

45

-

SS (5303260)

 

(45 Gallon Lawn & Garden Spot Sprayer)

 

OWNER

S MANUAL

 

Retain a copy of your receipt for your 

unit, as it will be required to validate 

any warranty service.

 

 

Warranted against manufacturer or 

workmanship defects from date of 

purchase with copy of receipt:

 

 

Homeowner Usage: Sprayer

-

One Year and Pump

-

Two Years.

 

 

Commercial Usage: Sprayer and Pump

-

90 Days.

 

BEFORE RETURNING THIS PRODUCT

FOR ANY REASON, PLEASE CALL

1-800-831-0027

MONDAY-FRIDAY, 8:00 AM TO 5:00 PM CST

If you should have a question or experience a problem with

your Fimco Industries Product: Visit our website @ 

www.fimcoindustries.com or call the Toll free number above. Our 

technical support representatives will be happy to help you. 

In most cases a customer service rep. can resolve

the problem over the phone.

To obtain prompt, efficient service, always remember to give the 

following information....

• Correct Part Description and

/or part number

• Model number and Serial Number

Part descriptions and numbers can be obtained from the

illustrated parts list section(s) of this manual.

General Information

 

Thank you for purchasing this product. The purpose of this 

manual is to assist you in operating and maintaining your 

 

spot sprayer. 

 

WARNING: 

Cancer and Reproductive Harm.

 

www.P65Warnings.ca.gov

 

WARNING: 

To reduce the risk of injury, the 

user must read and understand the operator

manual before using this product.

 

IMPORTANT:

 

Occasionally check your strainer screen to ensure it is 
clean and clear of any debris. Strainer is located on the 
end of the intake hose, inside of the tank. Use protective 
gear when removing hose from tank and cleaning the 
strainer.

 

Summary of Contents for LG-45-SS

Page 1: ...number above Our technical support representatives will be happy to help you In most cases a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s...

Page 2: ...yer Exercise Caution in vehicle handling when towing hauling a filled sprayer to avoid loss of control or overturning Keep Sprayer and Spray materials away from other people children and pets Do Not Turn on Power to the sprayer until ready to spray in order to avoid unintentional spray release Do Not Use on steep slopes A full sprayer could cause loss of control or overturn sprayer and vehicle Alw...

Page 3: ... chemical label s before application Operation The pumping system draws solution from the tank through the strainer and to the pump The pump forces the solution under pressure to the handgun Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Only fill the tank with what you re going to spray in a day never leave chemicals...

Page 4: ...u facturer s instructions on disposal of all waste water from the sprayer Tank Care Maintenance Warning Do not use the tank as a container for fuel oils kerosene gasoline or any other petroleum distillate product All polyole fins are softened and permeated by such products In an enclosed area the vaporization of these materials from the outside surface of the tank could create a dangerous conditio...

Page 5: ...rges Low flow may cause pump to surge Spray Wand is adjusted to small or fine of a Check for defective pressure switch Check for leaks in the discharge line Check for debris in nozzle orifice Fuse blows Excessive voltage Improper adjustment of pressure switch Damaged or defective wiring harness Defective pressure switch Pump continues to run Check for worn or dirty check valve Check for empty prod...

Page 6: ...ith the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If motor still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch still try this test Warning It is NO...

Page 7: ...Page 7 Exploded View Parts List LG 45 SS 5303260 Manifold Detail ...

Page 8: ...ice under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For ...

Reviews: