- 21 -
English language
GB
GYROS (GAS POWERED)
GAS PRESSURE CONTROL
Proceed as indicated.
1-
Close the gas supply faucet.
2-
Loosen the pressure fitting screw.
3-
Connect the pressure gauge to the pressure fitting.
4-
Open the gas supply faucet.
5-
Turn on the multi-burner, rotate the knob to the maximum power position.
6-
Make sure the pressure indicated on the gauge corresponds to the one on the appli-
ance plate.
7-
Turn off the burner, close the gas supply faucet and disconnect the pressure gauge.
8-
Tighten the screw.
EXTRAORDINARY MAINTENANCE
All extraordinary maintenance such as broken or worn component replacement must
be performed by authorised personnel with specific technical skills and special abilities
in the specific sector.
After maintenance (routine and extraordinary), always make sure that operations were
correctly performed before running the appliance.
Summary of Contents for GYR60
Page 4: ... 2 Lingua Italiana IT ...
Page 24: ......
Page 26: ... 2 English language GB ...
Page 46: ......
Page 48: ... 2 Langue française FR ...
Page 68: ......
Page 70: ... 2 Deutsche Sprache DE ...
Page 90: ......
Page 92: ... 2 Idioma español ES ...
Page 112: ......
Page 114: ... 2 Língua portuguesa PT ...
Page 134: ......
Page 136: ... 2 Русский язык PY ...
Page 157: ...IDM 34605600700 pdf SCHEMA ELETTRICO ELECTRIC DIAGRAM GYR60 ...
Page 158: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM GYR80 IDM 34605600800 pdf ...
Page 159: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM GYR60M GYR80M IDM 34605600900 pdf ...
Page 162: ......
Page 164: ......
Page 165: ......
Page 167: ......
Page 168: ......