FT-70 Fill Level Inspector Service Manual
6-34
Calibrating the Scintillation Tube Detector
The calibration procedure uses the Calibration LED on the
Calibration Board as an adjustment reference.
Scintillation Detector Calibration Procedure
1.
Clear the inspection tunnel of all containers so that nothing is
blocking the x-ray inspection beam.
2.
Turn the High Voltage Output Adjustment counterclockwise
until it stops.
Figure 6-3.
Calibrating the STD.
3.
Attenuate the inspection beam by placing a good production
container in the inspection tunnel so that it blocks the
inspection beam.
If your FT-70 is the extra wide inspection tunnel model, you do
not need to attenuate the inspection beam unless the LEDs are
constantly at maximum.
1
2
No.
Description
1
STD Calibration LED
2
High Voltage Output Adjustment
Industrial Dynamics Company, Ltd. ©
40256-0600
Summary of Contents for FT-70c
Page 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Page 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Page 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Page 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Page 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Page 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Page 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Page 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Page 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Page 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Page 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Page 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Page 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Page 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Page 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...