Section 2: Agency Listings, Approvals, and Requirements
Install and maintain in accordance with NFPA 72. Detector spacing shall be in accordance to NFPA 72. End-of -line relays and resistors shall
be placed within the electrical box located and the end of the initiating circuit. Testing and maintenance should be performed according to
NFPA 72.
2.1 Federal Communications Commission (FCC)
The following information must be provided to the telephone company before the FCP-75 can be connected to the phone lines:
1.
This device may not be directly connected to coin telephone or party line services.
2.
This device cannot be adjusted or repaired in the field. In case of trouble with the device, notify the installing company or return to:
Fike Corporation
704 SW 10th Street
Blue Springs, MO 61015
1+816-229-3405
3.
If the FCP-75 causes harm to the telephone network, the telephone company will notify the user in advance that temporary
discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the user as soon as
possible. Users have the right to file complaints, if necessary, with the Federal Communications Commission.
4.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the
equipment. If this happens, the telephone company will provide advance notice to allow you to make the necessary modifications to
maintain uninterrupted service.
1.
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the wiring diagram of this
equipment is a label that contains, among other information, a product identifier in the format US: HS9AL10A2100. If requested,
this number must be provided to the telephone company.
2.
See manual for phone jack information.
3.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable
FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this
product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.
4.
The REN (ringer equivalence number) provided on this installation sheet is used to determine the number of devices that may be
connected to the public switched telephone network. This number must not exceed 5.0. Since this product has an REN of 1.0A, the
number of devices is limited. The REN number is embedded in the FCC registration number as 10A.
5.
If this equipment
FCP-75
causes harm to the telephone network, the telephone company will notify you in advance that temporary
discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as
soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
6.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of
the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary
modifications to maintain uninterrupted service.
7.
If trouble is experienced with the
FCP-75
, for repair or warranty information, please contact technical support at
(800)979-3453
or www.
fike.com
. If the equipment is causing harm to the telephone network, the telephone company may request that you
disconnect the
FCP-75
until the problem has been resolved.
8.
See warranty in back of this manual for repair and replacement information.
9.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or
corporation commission for information.
10. If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this
FCP-75
does not
disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or
qualified installer.
Electrical Safety Advisory:
Parties responsible for equipment requiring AC power should consider including an advisory notice in their customer information suggesting
the customer use a surge arrestor. Telephone companies report that electrical surges, typically lightning transients, are very destructive to
customer terminal equipment connected to AC power sources. This has been identified as a major nationwide problem.
A
Manufacturer:
Fike
B
Model Number:
FCP-75
C
FCC registration number:
US: HS9AL10A2100
Ringer equivalence:
1.0A
D
Type of jack:
RJ31X
E
Facility Interface Codes:
Loop Start: 02LS2
F
Service Order Code:
9.0F
!
WARNING: FCC RULES PART 15
THIS DEVICE HAS BEEN VERIFIED TO COMPLY WITH FCC RULES PART 15. OPERATION IS SUBJECT TO THE
FOLLOWING CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE RADIO INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Summary of Contents for FCP-75
Page 144: ...Cut along dotted line ...
Page 145: ...FCP 75 Manual P N LS10147 003FK E A 3 17 2021 145 ...