S
ERVICE
P
ROCEDURES
70
Updating the system
After you verify that the system functions properly with the new motherboard, you must
update it as described in the following procedure.
N
OTE
:
Updating the system permanently customizes the new motherboard. Once customized,
the motherboard cannot be returned to inventory or installed in another E-8100. If the new
motherboard did not solve the problem in Service Mode (see
), do not update the
system. Return the new motherboard and unused one-time use dongle to inventory.
N
OTE
:
The replacement motherboard kit may include a different update CD and update
procedure than described below. Use the update CD and update procedure included in the
replacement motherboard kit.
T
O
UPDATE
THE
SYSTEM
N
OTE
:
This procedure assumes that E-8100 is fully assembled, powered on, and verified in
Service Mode (see
).
1. Make sure that the one-time use dongle is firmly attached to a USB port on the E-8100 and
that no other dongles or USB storage devices (such as a Flash or thumb drive) are attached to
the E-8100.
If the one-time use dongle is not attached:
• Power off the E-8100.
• Remove all dongles (such as Impose or Compose) and USB storage devices that may be
installed on the front and back of the E-8100.
• Connect the one-time use dongle (see
).
• Power on the E-8100 using the power button on the front panel.
2. Insert the Feature Update CD into the DVD drive.
3. From the Control Panel, select Reboot System (see
Allow the E-8100 to shut down and reboot.
4. At the following screen, select Update System.
If an error message displays on the Control Panel, see
5. At the following screen, select Yes.
Update System
Exit
Update CD
Select
Continue with
system update?
YES
NO
Select