background image

01

03

06

02

05

04

07

09

12

08

11

10

Quick Start

Wireless Operation

1. Select DC or AC switch position, 

depending on accessory head.

2. Select RECV or SEND, depending 

on operation you want to perform.

3. Hold SYNC for one second. Search 

pattern will initiate on display while 

searching for partner device.

4. Set partner device to appropriate 

switch position.

5. Hold SYNC on partner device for 

one second. Signal bars and battery 

info of partner device will display on 

EH4W when connection is made.

6. Enjoy the wireless goodness!

Certifications

 

 

C-Tick (N22675)

  

 

 

CE  EN 61326-1

   FCC

   WEEE

 

 

RoHS compliant

Description

As a new owner of EH4W you can 

now wirelessly receive measurements 

from anywhere on the jobsite and be 

free from tangled wires. Your EH4W 

can be set up to send you indoor 

wet bulb measurements over-the-

air for real-time target superheat 

calculations while you are outside at 

the condenser taking actual superheat 

readings.

Take measurements in multiple 

places at once and have them sent 

wirelessly to you anywhere you are 

on the jobsite. 

Your EH4W can wirelessly receive 

measurements from any Fielpiece 

transmitters and display the readings 

wherever you are on the job.

EH4W also converts any Fieldpiece 

accessory head into a wireless 

transmitter to send your measurement 

over-the-air to a Fieldpiece wireless 

receiver like the HG3, LT17AW, or 

EH4W. This allows you to set up your 

accessory heads and monitor your 

measurements from anywhere on 

the jobsite.

Your EH4W easily syncs with 

compatible wireless Fieldpiece 

transmitters and receivers. EH4W has 

a wide wireless range to cover the 

whole jobsite. 

Fieldpiece

Wireless Electronic 

Accessory Head 

Handle

OPERATOR'S 

MANUAL

Model EH4W

Specifications

Wireless range:

  Up to 75 feet (23m) line of sight

Minimum Wireless Distance:

  Up to 1 foot (30cm)

Wireless Frequency: 

910MHz to 920MHz (US), 

868.1MHz to 868.5MHz (European)

Display:  

5000 count FSTN LCD

Measurement Rate:

 2.5 times per second, nominal

Overrange:

 (OL) or (-OL) is displayed 

Accuracy:

 Stated at  73

o

F ±9

o

F (23°C ±5°C), <75% RH

Temperature Coefficient:

 0.1 x (specified ac-

curacy) per °C [0°C to 19°C (32°F to 66°F), 28°C 
to 50°C (82 °F to 122°F)]

Auto Power Off:

  Approx. 30 minutes

Low battery indicators:

 An empty battery icon

  on LCD will indicate when batteries must 

be replaced. Battery in lower left is for EH4W. 
Battery in upper right is for partner device.

Power:

 Single standard 9-volt battery, NEDA 1604, 

JIS 006P, IEC 6F22

Battery life:

 200 hrs typical with alkaline

Operating enviroment:

 32

o

F to 122

o

F (0°C to 50°C) 

at <70% relative humidity

Storage temperature: 

-4

o

F to 140

o

F (-20°C to 

60°C), 0 to 80% RH (with battery removed)

Dimensions: 

140mm(H) x 59.2mm(W) x 33mm(D)

Weight:  

Approx. 125g including battery

Safety:

  Designed to meet CE-EMC.

DC Volts:

Ranges: 500mV, 5000mV (Auto)
Resolution: 0.1mV (500mV), 1mV (5000mV)
Accuracy: ±(0.5%rdg + 3dgts)
Input Impedance: 1MΩ
Input protection: Max 30 VDC or 24VAC rms

AC Volts (50Hz - 500Hz)

Ranges: 500mV, 5000mV (Auto)
Resolution: 0.1mV (500mV), 1mV (5000mV)
Accuracy:  ±(1.2%rdg + 6dgts), 50Hz-100Hz 
 

±(1.5%rdg + 6dgts), 100Hz-500Hz

Input Impedance: 1MΩ
Input protection: Max 30 VDC or 24VAC rms

Safety Symbols Used
 

Caution, refer to manual.

 Ground

 

Double Insulation

How to Use

Normal Display Mode

1. Connect any Fieldpiece accessory 

head to EH4W. 

2. Select DC switch position for all 

accessory heads expect the ACH4 

current clamp (AC).

3. Select SEND switch position.

Transmitter Mode

EH4W

1. Connect any Fieldpiece accessory 

head to the EH4W by sliding it onto 

the top of the handle.

2. Select AC switch position for ACH4 

current clamp or DC for all other 

accessory heads.

3. Hold the RANGE (SYNC) button for 

one second.

Note: Search pattern on LCD will initi-

ate. Once a connection is made, the 

signal bars will stay solid represent-

ing signal strength.

Note: The signal strength and battery 

condition of the EH4W will be dis-

played on the receiver  LCD when a 

connection is made.

Note: If no signal is found within two 

minutes, EH4W will turn off.

Receiver (LT17AW, EH4W, HG3)

4. Select RECV switch position. Hold 

SYNC button for one second. For 

HG3, highlight the test line and hold 

SYNC button for one second.

Note: If no signal is found in two min-

utes, NSG will display. Press SYNC 

button for one second to re-sync.

Receiving Mode

EH4W

1.Select RECV switch position. Then 

Hold RANGE (SYNC) button until 

it beeps.

Note: If no signal is found within two 

minutes, EH4W will stop search-

ing. Once connection is made, the 

signal strength and battery life of 

the partner device will be displayed 

on EH4W.

Transmitter (ET2W)

1. Connect any Fieldpiece accessory 

head.

2. Select AC switch position for ACH4 

or DC for all other accessory heads.

3. Hold SYNC button for one second.

Transmitter (EH4W)

1. Connect any Fieldpiece accessory 

head.

2. Select SEND switch position. Hold 

RANGE button until beeps to sync. 

Transmitter (LT17AW)

1. Select the desired measurement 

range on the dial.

2. Hold SYNC button for one second.

Auto-Connection

The above operations are to 

synchronize wireless devices for the 

first time. When powered on, EH4W 

will automatically connect to the 

last single-link receiver (LT17AW, 

ET2W, or EH4W) or transmitter it was 

sychronized to. No need to constantly 

sync the same pair.

Data Hold, Max, Min

Data Hold, Max, and Min are only 

used when EH4W is in SEND switch 

position. Data Hold, Max, and Min are 

disabled in RECV switch position.

1. Press HOLD/MAX/MIN to freeze the 

current reading on the display.

2. Press HOLD/MAX/MIN again to 

show the highest (MAX) reading. 

Press HOLD/MAX/MIN a third time 

to show the lowest (MIN) reading.

3. Pressing HOLD/MAX/MIN will cycle 

through these settings in the above 

order.

4. Hold the HOLD/MAX/MIN button 

for one second to exit and return 

to real-time display.

Auto Power Off

Auto Power Off (APO) is automati-

cally disabled when EH4W is wirelessly 

connected to a partner device. APO 

can be manually disabled by holding 

the HOLD/MAX/MIN button while 

turning the switch from OFF to any 

other switch position.

Maintenance

Clean the exterior with a dry cloth. 

Do not use liquid.

Battery Replacement

The battery on the EH4W must be 

replaced when the lower left battery 

icon( 

 ) is empty. At this point, the 

EH4W will display "bAtt" on the screen 

accompanied by a continuous beep. 

The meter will turn off in 5 seconds 

and no further measurement will be 

allowed until the battery is replaced.

More Wireless...

Easily add to your wireless arsenal 

any Fieldpiece accessory head with 

ET2W transmitters. HG3 Multi-Channel 

Wireless Analyzer receives wireless 

readings from multiple transmitters.

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEAD!

PRESS FOR 1 SEC TO EXIT

AUTO-OFF

SEND ONLY

EH4W

DC

AC

CAT.III

300V
400A

CLAMP

ACH4

AC Current

Clamp

1AAC / 1mVAC

400AAC MAX

!

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

AUTO OFF

ARH4

ET2W w/ ARH4

transmitting wirelessly 

to EH4W

MAX 30VDC

24VAC

CONNECT ONLY TO

ACCESSORY HEAD

!

PRESS FOR 1 SEC TO EXI

T

AUTO-OFF

SEND ONLY

EH4W

DC

AC

!

!

  WARNINGS  

!

Use only with Fieldpiece accessory heads. Accessory 

heads deliver low voltage (under 2V) to the EH4W. 

Voltages higher than 30VDC or 24VAC rms can damage 

the EH4W.

DO NOT CONNECT EH4W TO LINE VOLTAGE!

CAT.III

300V
400A

CLAMP

ACH4

AC Current

Clamp

1AAC / 1mVAC

400AAC MAX

!

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

ET2W

LO BATT

SEND

RECEIVE

ON

AC

DC

Wireless

Transmitter

SYNC

AUTO OFF

ARH4

ET2W

with ARH4

ET2W

with ACH4

ET2W

with ACM3

Clea

r

Input

Output

Recall

Enter

Save

Sync

SETUP

Target

Evaporator

Logger

Light

Exit Temp

CFM

Display

Superheat

Subcooling

Combustion

HVAC  Guide

CheckMe!

Fieldpiece HG3

Data

Service

Display

INPUT FORM

SET 01

Set ID:Indoor Temp

Measurement: 

72.8

SET 02

SET ID:Comp Amps

Measurement: 

23.6

CustomerID

: __JONES123

HG3 Multi-Channel 

Wireless Receiver 

data logging 

multiple readings at 

the same time

Reviews: