Please retain these instructions after installation.

This device MUST be installed by a qualifi ed agency in accordance with the manufacturer's installation instructions. The defi nition of 
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged 
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 
precautions required, and has complied with all the requirements of the authority having jurisdiction.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

BLOCKED VENT SWITCH 

Model: WMO-1

WARNING:  Do NOT reset the device or restart the appliance unless the cause has been identifi ed 
and corrected by a qualifi ed agency. Ensure the switch appliance combination has been cleaned by 
a qualifi ed agency before placing back into service. Annual inspection and cleaning by a qualifi ed 
agency is required.

•  Wiring MUST be in accordance with the current Canadian Electric Code and any other applicable 

federal, provincial and local code requirements.

•  For installations in the USA, all wiring shall be in accordance with the National Electrical Code and 

applicable local codes.

•  For continued safe operation, the appliance-switch combination is required to be inspected and 

maintained annually by a qualifi ed agency.  Failure to properly maintain the appliance-switch 
combination can lead to Death, Personal Injury and or Property Damage.

The WMO-1 Blocked Vent Switch is recommended for installation with an oil fi red appliance that normally 
operates with its vent system under a  negative pressure. This device is intended to detect a blocked vent 
system, responds to hot fl ue gases backing up through its heat transfer tube, and can be wired to shut off  
the oil burner. It requires manual resetting.

WARNING:  Read the installation instructions carefully and completely before proceeding with 
the installation.

ITEMS INCLUDED IN KIT

1 -  Blocked Vent Switch Assembly
2 -  5/8” x 11 UNC Hex Jam Nuts
1 -  Instruction Sheet

Summary of Contents for WMO-1

Page 1: ...ervice Annual inspection and cleaning by a qualified agency is required Wiring MUST be in accordance with the current Canadian Electric Code and any other applicable federal provincial and local code...

Page 2: ...UFACTURER DOES NOT SUPPLY A WIRING DIAGRAM REFER TO DIAGRAMS A OR B Diagram A Honeywell R7184B Carlin 60200 02 INSTALLATION MOUNTING IN THE VENT PIPE SEE THE APPLIANCE MANUFACTURER S INSTRUCTIONS FOR...

Page 3: ...ldup or obstruction inside the heat transfer tube 7 Remount lock and refasten the control box with the two screws removed in step 4 8 Reattach the assembly cover with screws removed in step 2 9 Re est...

Page 4: ...page 4...

Page 5: ...ces en cours du Code canadien de l lectricit et de tout autre code en vigueur aux niveaux f d ral provincial et local Pour les installations aux tats Unis tout le c blage sera conforme au Code nationa...

Page 6: ...e l appareil de commande au moteur du br leur Voir Sch mas A et B Acheminer tout le c blage muni d une gaine de c ble acceptable conform ment aux exigences en cours de la norme CSA C22 1 Code canadien...

Page 7: ...rmique Le bo tier de commande coulisse en le d bloquant de l ensemble du tube de transfert thermique 5 Retirer avec soin tout d p t de la surface du commutateur thermique 6 D gager et liminer tout d p...

Page 8: ...52 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC P N 46520900 Rev C 04 16 Warranty For warranty information about this or any Field Controls product visit www fieldcontrols com wa...

Reviews: