Installation & Operation Manual
MiniSplitUV Model UV-30DL improves air quality and fights biological contamination
inside the air handling system. It extends the life of the air system and reduces maintenance
costs.
IMPORTANT!
•
Only qualifi ed technicians should install this product
•
Install in accordance with relevant building codes
•
Read instructions carefully including safety warnings
A
UV
Lamps
B
Lamp
Clips
C
Ballast
Assy
D
120V
Plug
E
Power
Harness
F
Zip
Ties
G
Adhesive
Strips
H
Air Flow Sensor
I
UV Warning Sticker
Installation Notes
MiniSplitUV is used for mini split systems and other limited space applications. Because
space is tight the best place for mounting the UV lights is usually inside the supply vent with
the light shining onto the blower wheel (which is prone to the worst mold growth).
Cutaway view of typical MiniSplit UV® installation in mini split
Parts Included:
Air System Preparation
1. Remove cover.
2a. Detach drain pan to access the
area behind it.
2b. For systems with non-removable
drain pan, remove louvers and baffl es
to access the area behind
3. Drill holes to pass lamp cables through to
back of unit as needed.
UV Lamp Mounting
1. Determine the best location
for the UV lamp clips and clean
that area with an alcohol wipe.
Slide the mounting brackets
onto the ends of the UV lamps.
3. Pass the UV lamp cables through to
the back of the AC system.
IMPORTANT!
Rotate the lamp so the warning sticker is visible and the UV light shines on
blower wheel and mold prone areas,
NOT INTO THE ROOM.
2. Peel off paper from the adhesive backing on
the mounting brackets. Press the lamp with lamp
clips fi rmly in place about 2” from blower wheel.
WARNING: Never expose eyes or skin to UVC light from any source. Looking
directly at the UVC light may casue permanent eye damage or blindness. Never
operate the UV-30 DL MiniSplitUV in an open area and in view of any person.
WARNING
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT BEFORE SERVICING
IMPORTANT!
Orient the UV lamps so that the light shines into the air system, not into the room.
P/N 780109300 RevA