background image

www.fi eldcontrols.com

Please retain these instructions after installation.

This device MUST be installed by a qualifi ed agency in accordance with the manufacturer's installation instructions. The defi nition of 
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged 
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 
precautions required, and has complied with all the requirements of the authority having jurisdiction.

Installation Date:

Installed By:

Phone:

Models: FC-60DH, FC-85DH, FC-120DH

DEHUMIDIFIER

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY 

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY 

BEFORE PROCEEDING WITH THE INSTALLATION.

BEFORE PROCEEDING WITH THE INSTALLATION.

P/N 780107800  09/21  Rev A

Summary of Contents for FC-120DH

Page 1: ...engaged in and is responsible for the installation and operation of HVAC appliances who is experienced in such work familiar with all the precautions required and has complied with all the requiremen...

Page 2: ...sert objects or your fingers into the inlet or discharge Do not insert objects or your fingers into the inlet or discharge Do not use water to clean the exterior of the dehumidifier To clean unit unpl...

Page 3: ...s means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room INSTALLATION INSTALLATION 1 Place dehumidifier on a level surface D...

Page 4: ...the setpoint the unit will operate Keep in mind that the displayed humidity levels are approximate 5 3 Continuous Mode To set the unit to run continuously regardless of humidity simply use the down ar...

Page 5: ...ice unless otherwise indicated If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode a...

Page 6: ...en the remote is powered on 1 On Off Power Button Press the on off button and the machine will start running Press the button again to turn the machine off 2 Up Button Down Button Use the up and down...

Page 7: ...n and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage During...

Page 8: ...the coils with an approved coil cleaner The coil cleaner should be a self rinsing foaming cleaner such as WEB Coil Cleaner Cleaning the Filter 1 Unplug the unit 2 For PreFilter a Remove prefilter fro...

Page 9: ...IDIFIER STORAGE If the unit will be stored for an extended period of time complete the following steps 1 Turn off the unit and allow it to dry 2 Wrap and secure the power cord 3 Cover the filter mesh...

Page 10: ...Code LO Room Temperature is below 33 F Increase the room temperature so it is within operating range above 33 F If error still displays check sensor Error Code HI Room Temperature is above 105 F Decr...

Page 11: ...X X 602609205 LG10C 10 Round Return Supply Collars set of 2 Large X 602609206 WHD1 RCK Remote Control Kit X X X 602609207 WHD2 HK Hanging Kit Assembly X X X 602609701 SM10PF WHD Prefilter replacement...

Page 12: ...te www fieldcontrols com WARRANTY WARRANTY For warranty information about this or any Field Controls product visit For warranty information about this or any Field Controls product visit www fieldcont...