background image

 

Page 4

INSTALLATION 

W

HERE TO INSTALL THE 

C

LEAR

W

AVE

™ 

1.  For domestic water applications, locate where the main water supply pipe enters the home or building.  For 

light commercial applications such as dishwashers, ice makers, boilers, water heaters etc., attach the 
ClearWave™ unit to the water supply line to that particular appliance. 

2.  Find a suitable location to install the ClearWave™ on the water supply pipe before the piping branches off 

to supply water throughout the home. 

H

OW TO INSTALL THE 

C

LEAR

W

AVE

™ 

1.  One set of mounting brackets are provided, for mounting the ClearWave™ onto 1/2” to 1-1/2” water pipes 

or wall mounted near the selected pipe area.  Mount the mounting brackets to the base of the ClearWave™ 
by using the screws provided.  Mount the ClearWave™ onto the pipe with wire ties or to the wall with 
appropriate fasteners.  (see Figure 1)  For pipe mounting, the wall mount tabs should be removed from the 
mounting brackets.  (see Figure 2) 

2.  Plug the antenna into each end of the housing.  If longer wires are needed, up to 50 feet of 12Ga stranded 

wire can be added to the antenna wires with an insulated butt end wire connector or they can be replaced 
with 65 feet of 12Ga stranded wire. 

 

Figure 1 

 

Figure 2 

Summary of Contents for CLEARWAVE CW-HD-1

Page 1: ...o magnetic low frequency wave pulses into the water These wave pulses produce water with remarkable anti scale properties without adding salts or chemicals at an operating cost for electricity of appr...

Page 2: ...ric potential applied changes the scaling characteristics of the calcium or magnesium without the removal of these ions or the addition of chemicals Magnets Bar magnets were the first types of equipme...

Page 3: ...n soluble and insoluble causes a disruption and weakening of the electrical field reducing the effectiveness on scale reduction Under these conditions an iron removal system is required to filter out...

Page 4: ...1 One set of mounting brackets are provided for mounting the ClearWave onto 1 2 to 1 1 2 water pipes or wall mounted near the selected pipe area Mount the mounting brackets to the base of the ClearWa...

Page 5: ...tom of the pipe first keeping the antenna wire tight against the pipe and the preceding coil Secure the end of the left antenna wire to the water pipe with a wire tie 3 When energized the ClearWave mo...

Page 6: ...sired temperature After 1 to 2 months Any scaly crust or stains in toilets or under taps should be significantly reduced No new stains or crust should form Mold that attaches to scale will begin to di...

Page 7: ...Page 7...

Page 8: ..._____ _______________________________ _______________________________ _______________________________ _______________________________ _______________________________ _______________________________ __...