39
11.4.2 Recall preset tare value from quick PLU
Procedures: -
1.
If more than one weighing platform is used, shift to the preferred platform.
2.
During normal operation status, press
[0]
and press
[Tare]
.
3.
Instrument displays
Recall
on LCD1.
4.
Press the preferred quick PLU number (0~9) and press
[Print/M+]
.
5.
Instrument displays
tare value recalled on LCD3 then returns to operation status.
At this point, selected preset tare value is recalled and in effect.
11.4.3 Clear preset tare value from quick PLU
To clear preset tare value from quick PLU, follow paragraph
11.4.1
and enter zero value in step
2
.
11.5 Product Code and Product Description
13
11.5.1 Create & save product code and product description to quick PLU
Procedures: -
1.
Go to F19 and press
[Print/M+]
.
2.
Press
[PF/Set] or [MR]
until
P Code
appears on LCD2 and press
[Print/M+]
to confirm.
3.
Instrument displays H code followed by the 1
st
6 digits. Enter the first 6 digits of the code here
and press
[Print/M+]
to confirm.
4.
Instrument displays M code followed by the 2
nd
6 digits. Enter the 7
th
~ 12
th
digits of the code
here and press
[Print/M+]
to confirm.
5.
Instrument displays L code followed by the 3
rd
6 digits. Enter the last 6 digits of the code here
and press
[Print/M+]
to confirm.
6.
Instrument displays first 6 digits of description content.
7.
Enter description starting from H, then M1, M2, M3 and finally L. Press
[Print/M+]
to confirm and end
editing after last digit has been input.
8.
Instrument displays
PLU = ?
on LCD3.
9.
Save product code and product description to a preferred quick PLU by entering the quick PLU
number (01~99) and press
[Print/M+]
.
10.
Instrument displayed
Done
on LCD3.
11.
At this point, customer code and customer description are saved and in effect.
11.5.2 Recall product code and product description from quick PLU
Procedures: -
1.
During normal operation status, long press any numeric number key (0 ~ 9).
2.
Press
[PF/Set]
or
[MR]
until P
Code
appears on LCD1 and press
[Print/M+]
.
3.
Instrument displays
PLU = 00
on LCD3.
4.
Enter the 2-digit PLU number then press
[Print/M+]
.
5.
Instrument displays
customer code on LCD3.
6.
At this point, selected product code and product description is recalled and in effect.
11.5.3 Clear product code and product description from quick PLU
To clear product code and product description quick PLU, follow paragraph
11.5.1
and press
[Clear/x10]
and
press
[Print/M+]
in step 3.
13