60
18. Error Codes
Error
Code No.
Description
Err 1
Time value error
Err 2
Date value error
Err 3
Exceed manual zero
Err 4
Offset out of range / unstable during power on (5
minutes for OIML and NTEP mode)
Err 5
No load cell detected
Err 6
Tare operation error
Err 7
Logic error. HI limit set is lower than LO limit (and HI is
not = 0)
Err 8
Logic error. LO limit is higher than HI limit (and HI is not
= 0)
Err 10
(F25 Mode 3) Container weight is higher than tArE H
Err 11
(F25 Mode 3) Container weight is lower than tArE L
Err 12
(F25 Mode 3 and Mode 4) Actual weight is higher than
SP3
Err 13
Exceed maximum power on (5 minutes for OIML and
NTEP mode)
Err 19
Capacity or division setting error (Division set is higher
than 10000d)
Err 22
Manual Zero and Tare stability error
Err 23
Capacity setting error, Capacity 1 > Capacity 2
Err 24
Division setting error, e1 > e2
Err 25
Span gain is too low
Err 26
Not able to obtain stable status for longer than 10 sec
Err 27
Theoretical calculated value per e of Cal 2 varies more
than 1% as of Cal 1. Properly a load cell problem.
Err 28
Maximum accumulation limit is exceeded.
Summary of Contents for 19e
Page 2: ...2 ...
Page 63: ...63 22 Appendix B PC Output Protocols ...
Page 64: ...64 ...
Page 65: ...65 ...
Page 73: ...73 Fidelity Measurement Co Ltd http www fi measurement com e mail info fi measurement com ...