4
.
www.fidelissecurity.com
Copyright © 2022 Fidelis Cybersecurity
®
, Inc. All rights reserved
4. Collector SA Networking Environment
Collector SA appliances use the Admin network for service and inter-node communication. The
appliances also offer the iLO / IPMI interface for optional out-of-band management of the appliance.
Use the tables below to identify the count and type of switch ports necessary to support the number of
appliances in your deployment.
Admin Network
The Admin network connects the Collector SA to the Fidelis sensors and CommandPost systems.
Appliance
Switch Port Type
Qty
Collector SA
GbE Copper RJ45 port
1
iLO / IPMI Network
The iLO / IPMI network is an optional network for remote/out-of-band server administration.
Appliance
Switch Port Type
Qty
Collector SA
GbE Copper RJ45 port
1
5. Appliance – Logical Network Configuration
You must assign logical network information to each physical connection. Build a table of the logical
information for each appliance (sample below) that you can reference during configuration.
has a worksheet you can use.
Sample Network Configuration Table
Network Setting
Assignments
Interface
Admin (eth0)
iLO / IPMI
Hostname (FQDN)
CollectorSA-1.organization.net
Static IP Address
10.1.2.3
10.2.3.3
Subnet Mask
255.255.255.0
255.255.255.0
Gateway
10.1.2.1
Proxy Server
10.5.6.7
DNS Servers
8.8.4.4, 8.8.8.8
NTP Servers
pool.ntp.org
Time Zone
UTC (+0)