Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 130 of 254
Command
Description
AT+CLCK="FD",1,"<wrong PIN2>"
+CME ERROR: incorrect password
AT+CLCK="FD",1,"<wrong PIN2>"
+CME ERROR: incorrect password
AT+CLCK="FD",1,"<wrong PIN2>"
+CME ERROR: SIM PUK2 required
AT+CPIN?
+CPIN: SIM PUK2 //PIN2 is blocked. The PUK2 is needed for unlocking.
OK
AT+CPIN="<PUK2>","<NEW PIN2>" //Enter PUK2 and new PIN2
OK
Reference
3GPP TS 27.007
8.1.4 +CPWD, Change Password
This command sets a new password for the facility lock. The password can only be changed once the
required facility is enabled by the +CLCK command.
A password can be changed only if the provided password <oldpwd> has been verified. The entered
password <newpwd> must also comply to the password rules. The facility value <fac> is not
case-sensitive. In the password value, letters are not allowed.
Command
Description
Set
[Function]
Set a new password for the facility lock.
[Syntax]
AT+CPWD=<fac>,<oldpwd>,<newpwd>
[Response/Action]
OK
or:
+CME ERROR: <err>
Read
N/A