3.3.1.2 Power-on Timing
Figure 3-6 Power-on timing control diagram
Note:
Before pulling down the PWRKEY pin, make sure that the VBAT voltage is stable. It is
recommended that the interval between power up VBAT and pull down PWRKEY pin should not
be less than 30ms.
3.3.1.3 Auto Power-on
If the module is required to power on automatically, the PWRKEY pin can be directly connected to the
ground. The module can only be shut down if it is powered off in this mode.
3.3.2 Module Shutdown
The module supports the following three shutdown modes:
Shutdown
Mode
Shutdown Method
Applicable Scenario
Low voltage
shutdown
When VBAT voltage is too low or
powers down, the module will shut
down
The module does not shut down through normal
process, i.e., does not log out from the base
station
Hardware
shutdown
Pull down PWRKEY (for at least
3.1s) and then release
Normal shutdown
AT shutdown
AT+CPWROFF
Software shutdown