4.2.2 Description of Pins
The logic signal lever of H330S series is 1.8V. Pins of H330S series are described in the table below:
Pin #
Pin Name
I/O
Reset
Value
Idle
Value
Description
Power Supply
59
VBAT
I
Main power supply, voltage range: 3.3V ~
4.2V.
60
VBAT
I
61
VBAT
I
62
VBAT
I
64
VPA
O
Test pin for power supply of RF power
amplifier .Idle state in actual use.
1
VTRX
O
Test pin for transceiver power supply .
Idle state in actual use
46
VIO
O
1.8V voltage output inside the modules.
47
VRTC
I/O
Backup battery input/output.
Power ON/OFF Signal
48
POWER_OFF
I
PU
PU
Power off control signal, internal 4.7K
pull-up resistor
49
POWER_ON
I
PU
PU
Power on control signal, internal 200K
pull-up resistor
Reset Signal
77
RESET_ALL_N
I
PU
PU
External reset signal input, internal 200K
pull-up resistor
USIM Interface
4
USIM_CD
I
PU
PU
Insert USIM card to test; active low;
Internal 390K pull-up resistor.
5
USIM_VCC
O
USIM card power supply: 1.8V or 3.0V
6
USIM_RST
O
PP
PP
USIM card reset signal.
7
USIM_CLK
O
PP
PP
USIM card clock signal.
8
USIM_DATA
I/O
PU
PU
USIM card data signal, internal 4.7K
pull-up resistor.