Installation Instructions: Read these instructions in 
their entirety before performing any installation work.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications 

WPC-3 

ETL LISTED 

Conforms to UL STD 508; 
Certified to CSA STD  
C22.2 No. 14 

 

FOR USE WITH POOL AND SPA PRODUCTS 

Summary of Contents for WPC-3

Page 1: ...Instructions Read these instructions in their entirety before performing any installation work Rated for use on 110 120VAC 60Hz and 220 240VAC 60Hz applications WPC 3 ETL LISTED Conforms to UL STD 508...

Page 2: ...15003 00 Grounding Bar 9 2 94 15090 00 WPC Receiver 10 6 10 15086 04 Load Center Cover Plate Switch Bracket and Mounting Bracket Screws 11 5 10 15089 06 Terminal Block Mounting Screw 12 4 10 15060 01...

Page 3: ...04 12 12 Position Terminal Block 4b 1 41 15004 05 5 Position Terminal Block 5 2 42 15032 00 Timer 6 1 02 15269 00 Load Center Cover Plate 7 2 02 15267 00 WPC 2 Mounting Bracket 8 1 41 15003 00 Groundi...

Page 4: ...r associated equipment 1 A qualified electrician must install the WPC 3 in accordance to the National and Local Electrical Codes 2 The WPC 3 must not be less then 5 feet 3 meters in Canada from inside...

Page 5: ...hallenger C A CT HAGF FC 1 C Westinghouse or Bryant BR BQ GFCB FP 1 Crouse Hinds M P TRIPLEX M P GF GE Regular THOP THOP GF TQLFP 1 SUITABLE LISTED BREAKERS CIRCUIT BREAKER M ANUFACTURER FILLER PLATE...

Page 6: ...se see Fiberstars part no FP 1 2 WIRING INSTRUCTIONS FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS NEUTRAL LINE SECONDARY GROUND LINE PRIMARY Power Connections To...

Page 7: ...eaker Connect the NEUTRAL from the GFCI s LINE side to the Neutral bar on the Load Center Connect a wire from the 20 Amp circuit breaker to the T C POWER as shown on the diagram Connect a wire from th...

Page 8: ...2 terminal at one end and to the BLACK wire on the Fiberstars unit Connect the neutral to the NEUTRAL terminal in the WPC 3 and to the WHITE wire on the Fiberstars unit Connect the grounding cable to...

Page 9: ...the NEUTRAL bar at the breaker panel as illustrated Alternately you may connect the NEUTRAL from the device to the Relay and from the Relay to the NEUTRAL bar NOTE The 120VAC device is not to exceed 1...

Page 10: ...rminal on the terminal block Connect the 120V Primary from the 240V Circuit Breaker to the 120V PRI INPUT terminal Directly connect the 120V Secondary from the Circuit Breaker to the 2 Speed Pump NOTE...

Page 11: ...the 24V Valve control is energized to the NO Load circuit 24V Valve Wiring Optional Equipment To connect a 24V Valve follow diagram as shown Connect one leg of the 24V common to the 24V TO VALVE term...

Page 12: ...rs com 79 15097 00 REV B Page 12 of 20 FOR USE WITH TC 2 OPTION FOR USE WITH TC 2 OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION SINGLE SPEED INTERNAL...

Page 13: ...ars com 79 15097 00 REV B Page 13 of 20 FOR USE WITH TC 2 OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE WITH TC 2 OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION DUAL SPEED INTERNAL...

Page 14: ...er Extension To mount the Repeater carefully insert a small flathead screwdriver into groove between the Dome and Base approximately where the locking dimples are located Pry the Dome out of the locki...

Page 15: ...n the switch is returned to the REMOTE position simply use the wireless remote to turn OFF the units if desired Circuit 3 control For Synchronization of Circuit 2 and Circuit 3 Circuit 1 control Circu...

Page 16: ...h push of the button For Synchronization operation simply push the SYNC ON OFF button to turn ON and OFF the SPA Light and the Pool Light simultaneously If one of the lights is on when the SYNC button...

Page 17: ...f from 12 00 pm to 11 45 pm Once the time and time of operation has been set ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below To turn off timers...

Page 18: ...cated on the back of each receiver to release the cover NOTE Take notice of how the wires enter and exit the receiver and which receiver is connected to the Circuit 2 and Circuit 3 terminals on the te...

Page 19: ...DIP SWITCH Note Sample shown is of Channel 8 DIP SWITCH 1 2 3 Channel 1 OFF OFF OFF Channel 2 ON OFF OFF Channel 3 OFF ON OFF Channel 4 ON ON OFF Channel 5 OFF OFF ON Channel 6 ON OFF ON Channel 7 OFF...

Page 20: ...ed Pump Standard 3 2 Speed Pump w T C for Lo Speed T C for Hi Speed X Standard 1 Freeze Protect 2 T C w Relay for Pool Cleaner Booster Pump 5 FP T C w Relay for Pool Cleaner Pump EXAMPLE WPC3 3X2X 1 i...