Fiberplex VIM-1832 User Manual Download Page 1

 

 

 

USER

 

MANUAL

 

VIS

1832/VIM

1832

 

VRK-1832

VRK-1832

Made in the

USA

fiberplex.com • 301.604.0100

TECHNOLOGIES, LLC

TECHNOLOGIES, LLC

Primary

Aux

Aux

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

Sync

Power

S25-S32

Phantom

Power

S17-S24

Phantom

R1

S25

R2

S12

S17

S18

Power

S9-S16

Phantom

Power

S1-S8

Phantom

S9

S10

S1

S2

26

Clip

12

0

S28

R4

R3

S27

R5

S29

S20

S19

S21

S12

S11

S13

S4

S3

S5

26

12

26

12

26

0

0

0

12

0

26

12

0

26

26

0

12

0

0

0

0

0

26

12

26

12

26

26

12

26

12

26

0

12

0

0

0

0

0

26

12

26

12

26

26

12

26

12

26

0

12

0

0

0

0

0

26

12

26

12

26

26

12

26

12

12

12

12

12

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Clip

Summary of Contents for VIM-1832

Page 1: ...m R1 S25 R2 S12 S17 S18 Power S9 S16 Phantom Power S1 S8 Phantom S9 S10 S1 S2 26 Clip 12 0 S28 R4 R3 S27 R5 S29 S20 S19 S21 S12 S11 S13 S4 S3 S5 26 12 26 12 26 0 0 0 12 0 26 12 0 26 26 0 12 0 0 0 0 0 26 12 26 12 26 26 12 26 12 26 0 12 0 0 0 0 0 26 12 26 12 26 26 12 26 12 26 0 12 0 0 0 0 0 26 12 26 12 26 26 12 26 12 12 12 12 12 Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip C...

Page 2: ...Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the unit Values specified are applicable to the air inlets of the unit Condensation may not...

Page 3: ...king saves raw materials and reduces the volume of waste If you need to dispose of the transport packing materials recycling is encouraged Disposal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer or via the public waste disposal system ensuring any mat...

Page 4: ...n over greater distances more than 20 Km Complete electrical isolation Immunity to RFI and EMI Eliminates ground loop problems Can be routed overhead through walls or underground Avoids foot traffic while maintaining aesthetics Functional Considerations The LightViper VRK 1832 is an active device Because of this there are some aspects of this new technology that require some slightly different thi...

Page 5: ...ded to the LightViper VRK 1832 for increased functionality Additional Split Box es VIM 1032 The VIM 1032 is similar to the VIM 1832 mixer box in that it provides a parallel set of the snake s 32 input channels via an additional Fiber Cable in applications where you need splits for recording broadcast or monitor mixing The VRK 1832 Stage Box is fit with two split connectors for a total of three 1 V...

Page 6: ...ure between 0 and 50 C can be maintained If using the VIS 1832 configuration place the Stage Box in a location central to the majority of your signal sources Making Connections The setup of a basic 1832 system is a quick and simple process Connect a Fiber Cable between the primary fiber connection of the VRK 1832 and the primary fiber connection of the Tail End device VIM 1832 or VIM MY32M Make co...

Page 7: ... 0100 TECHNOLOGIES LLC TECHNOLOGIES LLC Primary Aux Aux 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 Sync Power S25 S32 Phantom Power S17 S24 Phantom R1 S25 R2 S12 S17 S18 Power S9 S16 Phantom Power S1 S8 Phantom S9 S10 S1 S2 26 Clip 12 0 S28 R4 R3 S27 R5 S29 S20 S19 S21 R6 S30 R7 S31 S22 S23 R8 S32 S24 S12 S11 S13 S4 S3 S5 S14 S15 S6 S7 S16 S8 26 12 26 12 26 0 0 0 26 0 12 0 26 12 0 26 0 26 26 ...

Page 8: ... there is no optical link present ALTERNATING GREEN AND RED means the unit is searching for sync SOLID GREEN indicates optical link is present and OFF indicates no power Fiber Connections Each Stage Box has one to three fiber connections The one marked Primary should always be connected to the Mixer Box VIM 1832 as it provides clock for the entire system Any other connections would be made to addi...

Page 9: ...place the fuse with an exact match If after replacement the fuse blows again return the unit for service Clip LED The Clip LED will flash at 3 dB below peak clipping 16 dBu Gain Switch Each input has 3 switch selectable gain settings 0 dB 12 dB and 26 dB The gain settings correlate to output levels as follows A setting of 0 an input signal of 0dBu will produce an output at the VIM 1832 of 0dBu A s...

Page 10: ...This page left intentionally blank ...

Page 11: ...24 AOut 25 AOut 26 AOut 27 AOut 28 AOut 29 AOut 30 AOut 31 AOut 32 AIn 1 AIn 2 AIn 3 AIn 4 AIn 5 AIn 6 AIn 7 AIn 8 DIn 1 2 DIn 3 4 DIn 5 6 DIn 7 8 DOut 1 2 DOut 3 4 DOut 5 6 DOut 7 8 DOut 9 10 DOut 11 12 DOut 13 14 DOut 15 16 DOut 17 18 DOut 19 20 DOut 21 22 DOut 23 24 DOut 25 26 DOut 27 28 DOut 29 30 DOut 31 32 WCLK In WCLK Out VIM 1032 PRx AOut 1 AOut 2 AOut 3 AOut 4 AOut 5 AOut 6 AOut 7 AOut 8 ...

Page 12: ...Specifications Figure 5 VRK 1832 Dimensions 19 00 482 6 8 72 221 4 3 97 100 8 30 7 5 41 10 3 17 00 431 8 18 33 465 5 5 75 146 0 ...

Page 13: ...Figure 6 VIS 1832 Dimensions 14 00 355 6 8 72 221 5 31 7 9 4 00 101 6 7 00 177 8 12 00 304 8 ...

Page 14: ...ED off indicates no power AC Power Universal 90 250 VAC 50 60 Hz Neutrik PowerCon connector with fuse Max Current Rating 0 473 mA 90V On Off Control Date MIDI RJ 45 connector for logic level control CMOS or TTL at 2 MHz max per channel Dimensions 12 5 L X 8 75 W X 4 H 32cm x 22cm x 10 cm Weight 12 lbs 5 44 Kg 1 Hum Noise are measured with an AES17 compliant filter at 20 kHz Temperature condition 1...

Page 15: ...er 3 Attenuation Bandwidth Numerical Aperture System Optical Data Rate System Operating Distance 1 dB Km 1300 nm 500 MHz Km 1300 nm 0 275 122 Mbs 2 Km 1 25 mi 1 Neutrik opticalCON 2 Four Channel Tactical Break Out Cable 0 30 7 5mm Outer Diameter Kevlar Strength Member 3 Graded Index Multimode Dual Window 850 1300nm CONTROL CIRCUITS RJ 45 PIN OUTS 1 GND 2 TX1 3 TX2 4 TX3 5 RX1 6 RX2 7 RX3 ...

Page 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 UMVRK1832 140807 ...

Reviews: