- 17 -
▶
Diagnostic Test
LED Calibration
Measures and adjusts the brightness of LED
Dust Check
Dust checking process
Motor Calibration
Automatically calibrates the motor speed
Arc Calibration
Automatically calibrates the Arc power
▶
LED Calibration
Measures and adjusts the brightness of LED
▶
Dust Check
Detects dust&contaminant causing improper splicing
In order to find out optimized position for splicing, the splicer analyses the fiber images being
transmitted by the optical camera & LED inside but dust or contaminant on the camera, lenses,
LED may cause inaccurate splicing results.
Therefore, the dust check process is recommended to proceed in case of frequent splicing fail
or high insertion loss.