OPERATInG THE DEVICE
#5: Operating the device
Controlling the Switch 2 using a momentary switch
and parameter 20 set to 0:
1x click:
• Change the state of the connected load to the opposite one
(S1 switches 1st channel, S2 switches 2nd channel),
• Change the state of 2nd, 3rd (S1 switch), 4th and 5th (S2 switch)
association group to the opposite one.
2x click:
• Set maximum level of devices associated in 2nd, 3rd (S1 switch),
4th and 5th (S2 switch) group.
Hold:
• Start smooth control of devices associated in 3rd (S1 switch) and
5th (S2 switch) group.
Release:
• Stop smooth control of devices associated in 3rd (S1 switch) and
5th (S2 switch) group.
NOTE
Momentary switch
After releasing the
switch a spring auto-
matically pushes back
and disconnects the
switch)
Toggle switch
Operates as a two-po-
sition switch, it has no
spring that would set
one position of the
switch.
i
Controlling the Switch 2 using a toggle switch and parameter 20
set to 1:
Close switch contact:
• Turn On the connected load (S1 switches 1st channel, S2 switches
2nd channel),
• Turn On devices associated in 2nd, 3rd (S1 switch), 4th and 5th
(S2 switch) group.
Open switch contact:
• Turn OFF the connected load (S1switches 1st channel, S2switches
2nd channel).
• Turn OFF devices associated in 2nd, 3rd (S1 switch), 4th and 5th
(S2 switch) group.
Controlling the Switch 2 using a toggle switch and parameter 20
set to 2:
Change switch position once:
• Change the state of the connected load to the opposite one
(S1 switches 1st channel, S2 switches 2nd channel),
• Change the state of 2nd, 3rd (S1 switch), 4th and 5th (S2 switch)
association group to the opposite one.
Change switch position twice:
• Set maximum level of devices associated in 2nd, 3rd (S1 switch),
4th and 5th (S2 switch) group.
NOTE
Toggle switch and
parameter 20 set to 1:
State of the device
is synchronized with
state of the external
toggle switches.
Toggle switch and
parameter 20 set to 2:
State of the device is
reversed with every
change in state of
the external toggle
switch.