REMOVING THE DEVICE

Removing (Exclusion)

 - Z-Wave device learning mode, allowing to 

remove the device from existing Z-Wave network.
To remove the device from the Z-Wave network:
1.  Make  sure  the  device  is  within  the  direct  range  of  your  Z-Wave 

controller.

2.  Set  the  main  controller  into  remove  mode  (see  the  controller’s 

manual).

3.  Use the included key to quickly triple click the button on the ther-

mostatic head.

4.  The LED ring will start blinking white.
5.  Wait for the removing process to end.
6.  Successful removing will be con

fi

rmed by the Z-Wave controller.

NOTE

Removing  the  device 

from  the  Z-Wave  net-

work  restores  all  the 

default  parameters  of 

the device.

i

#4: Removing the device

Summary of Contents for FGT-001

Page 1: ...u 10 9 Local protection 11 10 Head calibration 12 11 Standby Mode 13 12 Factory reset 14 13 Z Wave range test 15 14 Battery and charging 16 15 Normal Schedules 17 16 Override Schedule 18 17 Z Wave spe...

Page 2: ...Do not attempt to replace the battery General information about the FIBARO System FIBARO is a wireless smart home automation system based on the Z Wave protocol All of available devices can be contro...

Page 3: ...ed rotation spherical knob to set desired temperature FIBARO Heat Controller is a remotely controlled thermostatic head to control temperature in your room It measures the temperature and automaticall...

Page 4: ...urning it clockwise 2 Disconnect the charger when the LED ring pulses green device fully charged 3 Dismount your current thermostatic head 4 Depending on type of your thermostatic valve 5 Mount the de...

Page 5: ...Z Wave controller 2 Set the main controller in security non security add mode see the controller s manual 3 Use the included key to quickly triple click the button on the ther mostatic head 4 The LED...

Page 6: ...e controller 2 Set the main controller into remove mode see the controller s manual 3 Use the included key to quickly triple click the button on the ther mostatic head 4 The LED ring will start blinki...

Page 7: ...th colour depending on set temperature 3 Turn the sphere counter clockwise to lower temperature or turn clockwise to raise the temperature 4 Remove the hand from the sphere after 5 seconds LED will fa...

Page 8: ...nsor The device can be used with an additional dedicated temperature sensor FGBRS 001 to provide the best temperature regulation It can be placed anywhere in the room and the device will use it as a r...

Page 9: ...se the button when you see cyan LED colour 3 Click the button to confirm the selection 4 Turn the cap counter clockwise and remove adapter if used 5 Store the device in temperature 10 C to 25 C Before...

Page 10: ...n 2 Release the button when you see desired LED colour 3 Click the button to confirm the selection Colour Action Blue pair dedicated temperature sensor Red enable disable local control protec tion Whi...

Page 11: ...l protection is enabled The device will not set new target temperature The LED ring will blink red 3 times To change the temperature use the app or disable the local protection 9 Local protection To e...

Page 12: ...has been made only at first installation Automatically after 10 minutes from last state change only at first installation Manually using the menu see below Manually via application NOTE Calibration ca...

Page 13: ...Entering the device in Standby Mode will not factory reset the device nor will result in loosing any data 11 Standby Mode To enter Standby Mode 1 Use the included key to press and hold the button 2 Re...

Page 14: ...e included key to press and hold the button 2 Release the button when you see yellow LED colour 3 Click the button to confirm the selection 4 After finishing resetting the device will be put in Standb...

Page 15: ...y visual indicator pulsing yellow Glowing green the device communicates with the main controller directly Pulsing yellow the device tries to establish a routed com munication with the main controller...

Page 16: ...d main tains the last valve position CAUTION Makesureyouareusing certified charger Class II marked which complies with param eters specified in the manual To charge the battery 1 Connect charger to th...

Page 17: ...it Schedules allow to set target temperature for HEAT mode using Thermostat Setpoint CC and one of operating modes HEAT OFF or MANUFACTURER SPECIFIC using Thermostat Mode CC Only SET commands are perm...

Page 18: ...erature Setpoint for HEAT mode in range 10 30 C using Thermostat Setpoint CC One of the operating modes using Thermostat Mode CC HEAT for setting temperature OFF for valve fully closed MANUFACTURER SP...

Page 19: ...CIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL Description represents dedicated temperature sensor allows to check temperature and its battery level if not paired reported tem perature and battery level are alw...

Page 20: ...PORT_SERVICE 0x55 V2 ASSOCIATION_GRP_INFO 0x59 V2 YES DEVICE_RESET_LOCALLY 0x5A V1 YES MULTI_CHANNEL 0x60 V4 YES SUPERVISION 0x6C V1 YES NOTIFICATION 0x71 V8 YES MANUFACTURER_SPECIFIC 0x72 V2 YES POWE...

Page 21: ...GRP_INFO 0x59 V2 YES SUPERVISION 0x6C V1 YES NOTIFICATION 0x71 V8 YES BATTERY 0x80 V1 YES CLOCK 0x81 V1 YES PROTECTION 0x75 V1 YES SECURITY 0x98 V1 SECURITY_2 0x9F V1 Endpoint 2 ZWAVEPLUS_INFO 0x5E V2...

Page 22: ...vent Event Parameters Power Management 0x08 Charge battery soon 0x0E Charge battery now 0x0F Battery is charging 0x0C Battery is fully charged 0x0D System 0x09 System Hardware Failure 0x03 External se...

Page 23: ...able Open Window Detector 2 bit 1 enable fast Open Window Detector 4 bit 2 increase receiver sensitivity shortens battery life 8 bit 3 enabled LED indications when con trolling remotely 16 bit 4 prote...

Page 24: ...ions Diameter x Length EU Directive compliance 3 7V Li Poly battery pack non re placeable micro USB 5V DC 5 0 5A 0 40 C 10 25 C 90 C 0 5 C within 0 40 C range Type 1 class A grade Impedance Protected...

Page 25: ...d Maximum transmit power Z Wave 500 series chip 868 MHz ISM band for EU EIRP up to 4dBm For communication with the controller Radio frequency band Maximum transmit power 2 4 GHz ISM band EIRP up to 6d...

Page 26: ...equency band Maximum transmit power EU Directive compliance CR2032 3 0V battery included 0 40 C 10 40 C 0 5 C within 0 40 C range 38 x 12 mm 2 4 GHz ISM band EIRP up to 6 5dBm RoHS 2011 65 EU RED 2014...

Page 27: ...nder license All other brands and product names referred to herein are trademarks of their respective holders Warning This product is not a toy Keep away from children and animals CR2032 coin cells ar...