20
confIguratIon
9.2:
Advanced parameters
The device allows to customize its operation to user’s needs using
configurable parameters.
The settings can be adjusted via Z-Wave controller to which the de-
vice is added. The way of adjusting them might differ depending on
the controller.
In the FIBARO interface parameters are presented as simple options
in Advanced Settings of the device.
Available parameters:
1.
Remember device status before the power failure
This parameter determines how the device will react in the event
of power supply failure (e.g. power outage or taking out from the
electrical outlet).
After the power supply is back on, the device can be restored to
previous state or remain switched off. The sequence is not remem-
bered after the power returns. After power failure, the last color
set before the sequence will be restored.
Parameter size
1B
Default value
0
Available
values
0 - device remains switched off
1 - device restores the state from before the
power failure
20.
Input 1 - operating mode
This parameter allows to choose mode of 1st input (IN1). Change it
depending on connected device.
Parameter size
1B
Default value
2 (momentary switch)
Available
values
0 – Analog input without internal pull-up (Sensor
Multilevel)
1 – Analog input with internal pull-up (Sensor
Multilevel)
2 – Momentary switch (Central Scene)
3 – Toggle switch: switch state on every input
change (Central Scene)
4 – Toggle switch: contact closed – ON, contact
opened – OFF (Central Scene)