15
operatIng the DevIce
4. The device will signal the operating mode:
• 1 white blink – Single Switch mode,
• 2 white blinks – Double Switch mode.
7.3:
Button control
Controlling connected loads
Perform following actions on one of the buttons to change state of
the connected load. Button operation is configurable using parame-
ters 20 and 24.
Double Switch mode – the 1st button controls the 1st channel and
the 2nd button controls the 2nd channel:
• Click – change to the opposite state, ON/OFF (by default).
Single Switch mode – both buttons control the load:
• Click – change to the opposite state, ON/OFF (by default).
Other actions
Perform following actions on one of the buttons to:
• 3xClick – start learn mode to add/remove to/from Z-Wave network,
• 1,2,3xClick/hold/release – activate scene in the controller for spe-
cific action (requires configuration using parameters 40 and 41),
• 3xClick then press and hold – enter the menu.
7.4:
Visual indications
The built-in LED light shows current device status.
After powering the device:
• Green – device added to a Z-Wave network (non-secure, S0, S2
non-authenticated),
• Magenta – device added to a Z-Wave network (Security S2
Authenticated),
• Red – device not added to a Z-Wave network.
State of the device:
• White – load turned ON (configurable using parameters 11 and
12).
Update:
• Blinking cyan – update in progress,
• Green – update successful,
• Red – update not successful.