Potentiometric wire linear transducers

PFA3000T-12000T

Data: 13/01/16

File:  PFA_T_ing.doc

Pagina: 1 di 6

USER’S MANUAL AND MAINTENANCE

LINEAR POTENTIOMETER WIRE-TRANSDUCER WITH ANALGOUE OUTPUT

PFA3000T, PFA4000T, PFA5000T, PFA6000T, PFA8000T, PFA10000T, PFA12000T

Summary of Contents for PFA3000T

Page 1: ... transducers PFA3000T 12000T Data 13 01 16 File PFA_T_ing doc Pagina 1 di 6 USER S MANUAL AND MAINTENANCE LINEAR POTENTIOMETER WIRE TRANSDUCER WITH ANALGOUE OUTPUT PFA3000T PFA4000T PFA5000T PFA6000T PFA8000T PFA10000T PFA12000T ...

Page 2: ...d those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not need a particular maintenance except cleaning to do only wi...

Page 3: ...ecision rotating potentiometer operated by a winding or unwinding stainless steel wire Stroke of 3200 mm for PFA3000T 4200 mm for PFA4000T 5200 mm for PFA5000T 6200 mm for PFA6000T 7200 mm for PFA7000T 8200 mm for PFA8000 Linked together to an electronic display for example V3_ V4_ VE6_ it supplies a simple and effective system to measure linear motions on cranes rolling shutters automatic wood ma...

Page 4: ...id damage to persons or things c The instrument CANNOT function in a dangerous environment inflammable or explosive The unit has sensible parts to electrostatic charge therefore the handling of the inner electronic cards has to be carried out with appropriate care to avoid permanent damages The working temperature has to be between 0 50 C Power supply a Before connecting the instrument check that ...

Page 5: ...go in position 1 10Volt o 20mA in output with the cable all inside To calibrate the output in voltage link a voltmeter on the terminals 3 and 5 of the terminal block To calibrate the output in current link a milliammeter on the terminals 4 and 5 of the terminal block Position the cable of the transducer on minimum position of the analogue output then turn the trimmer T1 to bring the value of the o...

Page 6: ... IP54 Working temperature 0 50 C Relative humidity 35 85 Weight 1500 gr Case Anodized aluminium Cable entries cable gland PG7 per cable ø 3 6 mm Electrical connection Terminal block Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 341 ...