FIAMA F18-K User And Maintenance Manual Download Page 1

Display for magnetic band

F18-K

Date: 13/01/16

File: F18_K ing.doc

1/8

USER AND MAINTENANCE MANUAL

“F18-K“ DISPLAY FOR MAGNETIC BAND

WITH INTERNAL BATTERY POWER SUPPLY

Summary of Contents for F18-K

Page 1: ...Display for magnetic band F18 K Date 13 01 16 File F18_K ing doc 1 8 USER AND MAINTENANCE MANUAL F18 K DISPLAY FOR MAGNETIC BAND WITH INTERNAL BATTERY POWER SUPPLY ...

Page 2: ...d to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instrument does not needs a particular maintenance except cleaning to do only with a soft clo...

Page 3: ...nt tools and the offset function for balancing of tool wear On the display all activated functions are showed by a symbol The keys enabling to recall the preset dimension and the absolute relative dimension switches may be inhibited in a very simply way On the display all activated functions are showed by a symbol The power supply is internal with 2 batteries type AA of 1 5V one year life The run ...

Page 4: ...arameter press two times RESET one time displays only the value and with keys and set the wanted value to be confirmed with RESET To go out of the programming press 0 0 0 0 Value to be displayed for 100 mm of sensor displacement This parameter together with the following allows the programming of the value on the display for a certain displacement of the sensor It means that is necessary to set th...

Page 5: ...ar two small arrows and the indication of the selected origin happens with the switching on of the origin indicators see paragraph meaning of symbols After setting 4 in the first digit on the right of will appear PrS0 and pressing 2 times RESET has to be set the value to be read in this position of sensor for origin 0 confirm with RESET It will appear PrS1 which is the value to be read for origin ...

Page 6: ...ollows placed on a side of the instrument Take off the cover and take out the battery holder and change the batteries paying attention to the polarity indicated Without batteries the instrument switches off in this phase do not rotate the hollow shaft to avoid loosing of correct quota As soon as the batteries are fitted inside the instrument switches on with the same value on the display as at the...

Page 7: ... 01 16 File F18_K ing doc 7 8 Dimensions Connection scheme for versions with connector View of the male connector on the back of the instrument Note the connection of the shield is always necessary 1 2 3 1 BROWN 2 WITHE 3 YELLOW GREEN SHIELD ...

Page 8: ...display IP67 sensor Sensor cable Length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house aluminum black Dimensions 48x72 depth 60mm Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via ...