24
Phone Settings
3.2.2.3
You can configure the "hardware behaviour" of the InduTel IP here.
Relay Activation
There are five options available.
"on/off"
generally switches the relay on or
off. If
"incoming call"
is
selected, the relay switches to
"on"
for as long as
there is an incoming call. Selecting
"active call"
on the other hand ensures
that the relay is on
"on"
for as long as an existing connection is active. The
"switch"
function makes it possible for the relay to be controlled locally from
the InduTel IP.
Switch Function
Switching the relay with an active connection is not possible. The code is en-
tered here which must be entered via the keypad (an
"internal call"
is in-
volved) when the handset is off its hook in order for the relay to jump to
"on"
for a certain period of time
(time parameter)
before falling back into the
"off"
status again. Calling numbers/blocks beginning with the dialed code are
no longer available as a telephone number. The default setup is
"*1234"
.
Handset Rest Lights
With this parameter, the handset rest lighting can either be turned on or off or
be configured as an additional optical signal. If the point
"incoming call"
is
selected, the LEDs start flashing while the InduTel IP rings.
Keypad Backlights
The keypad backlights can be turned on or off. Additionally, it is possible to
set them to turn on when the handset is off hook by selecting
"off hook"
.
Summary of Contents for InduTel IP
Page 1: ...IP Weatherproof telephone FHF BA 9605 05 09 16 V1 Operating instructions...
Page 13: ...13 2 4 Dimensions Figure 6 Dimensions in mm...
Page 23: ...23 Figure 11 SIP Settings...
Page 30: ...30 Figure 17 Reset Settings...
Page 45: ...45 Degree of protection in accordance with IEC60529 IP 66 closed...
Page 47: ......