Fetco TEAVARIS PLUS TBS-1221 Users Manual And Operator Instructions Download Page 8

Go to fetco.com for the latest versions of all information         

Page 8

      

User Guide & Operator instructions

  

P209

Re0

August 2021

 

B GENERAL 

Brewer Operation Control Settings, Adjust Brew Flow Rate

 

POSITION 

Program Items 

Factory set Default 

Programming Range 

Increments 

Notes 

B1 

Tank Temp. 

200°F-or-93°C 

170° to 207°F 

77° to 97°C 

1.0°F 

0.5°C 

Chart to correct for 

high altitude below 

B2 

Brew at Temp. 

“YES” 

ON/OFF 

YES/NO 

SEE NOTE BELOW  

B3 

Batch Temp 

OFF 

ON/OFF 

ON/OFF 

For tea brewing 

temperature for A190 

B4 

Show Tank 

Temperature 

YES 

YES/NO 

 

To display HW tank 

temperature on screen

 

B5 

Units of Measure 

TEMPERATURE 

° Fahrenheit 

Fahrenheit/Celsius 

C/F 

NOTE

: Overwrites 

user settings 

(see page 9)

 

B6 

Units of Measure 

VOLUME 

Ounces 

Ounces/Liters/Gallons 

Oz/L/Gal 

NOTE

: Overwrites 

user settings 

(see page 9)

 

B7 

Customer Name 

Off 

NO or YES 

 

For name on screen 

B8 

Customer Name 

(only if above is 

“ON) 

Scroll with batch keys 

A-Z;a-z;0-9 

16 characters total 

B9 

Demo Mode 

OFF 

DEMO ON/OFF 

 

Demonstrates the controls 

for training. Disables all 

components in demo mode

 

B10 

Eco Mode 

Off 

ON/OFF 

YES/NO 

If Selected: Lowers hot 

water tank temperature after 

preset time of inactivity 

B11 

Eco Idle Time 

(turns on if B10 active) 

1Hr 

1-6 hours 

1 hour 

Time of inactivity to go into 

ECO Mode 

B12 

Eco Idle Temp 

(turns on if B10 active)

 

169°F 

158-176°F 

1 degree 

Temperature that hot water 

tank is lowered to 

B13 

Filter Life 

OFF 

ON/OFF 

YES/NO 

Water filter life is accessed 

in G-Counters. This is user 

set and will display indicator 

to change water filter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREW AT TEMPERATURE DEFINITIONS 

DEFAULT: BREW AT TEMP:  “ON” 

 

 

(FACTORY  DEFAULT FOR BREWER) 

 

“BREW at TEMP:   

-Batch will not start if tank temperature 

 is below set point. 

-Display will show “HEATING” 

 and hot water tank temperature 

The “BREW START” entry buttons will not 

illuminate until the hot water tank reaches the 

selected temperature.   

 

 

Notifications shown on screen: 

TEXT: 

HEATING

Tank above 87°C/189°F-

will allow  brew at low temperature.   

Extracted tea flavor may be affected 

TEXT: 

L. HEAT

Tank above 76°C/169°F-

will allow brew at low temperature.   

Tea  flavor will be noticeably affected 

 

 

 

 

 

 

 

Tank temp

 

 

STOP is not lit

 

 

 

& BREW START 

buttons not lit. 

and 

are disabled

 

Batch menu 

 button(s ) will 

illuminate and 

“READY” will display 

on screen when hot 

water tank 

temperature is at 

setpoint 

 

 

 

Hot water tank not at 

brew temp setpoint.

 

HEATING 

160°F 

 

 

 

 

 

FETCO 

Ready to Brew 

 

 

 

 

 

USER SELECTABLE OPTION: BREW AT TEMP:

  

OFF

    

 

(Not recommended) 

 Unit will operate at reduced temperature

 

Allows brewing at any temperature above 169°F/76°C 

 

 

Chart to correct for altitude for boiling point   

in hot water tank water temperature.

 

[ft] 

[m]  Suggested 

Setting[°F] 

Boiling 

point[°F] 

Suggested 

Setting[°C] 

Boiling 

point [°C] 

205 

212.0 

96 

100.0 

500  152 

205

 

211.0 

96

 

99.5 

1000  305 

200

 

210.1 

93

 

98.9 

2000  610 

200

 

208.1 

93

 

97.8 

2500  762 

200

 

207.2 

93

 

97.3 

3000  914 

200

 

206.2 

93

 

96.8 

3500  1067 

197 

205.3 

92 

96.3 

4000  1219 

195 

204.3 

91 

95.7 

4500  1372 

194 

203.4 

90 

95.2 

5000  1524 

194 

202.4 

90 

94.7 

5500  1676 

193 

201.5 

89 

94.2 

6000  1829 

192 

200.6 

89 

93.6 

6500  1981 

191 

199.6 

88 

93.1 

7000  2134 

190 

198.7 

87 

92.6 

7500  2286 

188 

197.8 

86 

92.1 

8000  2438 

187 

196.9 

86 

91.6 

8500  2591 

185 

196.0 

85 

91.1 

STOP 

STOP 

Summary of Contents for TEAVARIS PLUS TBS-1221

Page 1: ...d Tea Brewer FETCO TEAVARIS PLUS Commercial Beverage Equipment TBS 1221 Single Dilution Teavaris Plus TBS 1222 Dual Dilution Teavaris Plus Shown with ITD dispensers not included CONTACT INFORMATION FE...

Page 2: ...es Electrical Specifications for single domestic 120 volt cord and plug SKU Dilution Electrical Connection Heater Configuration Voltage KW Amp Draw Est 3gal Batches Hour T1221US 1A117 PM001 Domestic S...

Page 3: ...n a receiving dispenser for the left or right side brew orientation TBS 1221 Single dilution has a square brew basket and is only positioned in the center for three recipes A1 A2 and A3 Two position b...

Page 4: ...ze and then display digital process notifications 3 After Initialization STOP Lamp turns on 4 Quickly press STOP button no need to hold When brewer is In PROGRAMMING MODE the screen will display BATCH...

Page 5: ...kup to USB G5 Choose Counter A17 Dilute Mode B6 Units of Volume D13 LED Brightness F9 Restore from USB G10 Brewer Volume LT A17 Dilute Delay B7 Customers Name F10 Restore Defaults G11 Brewer Volume R...

Page 6: ...after brew to begin dilution Often used to add sweetener A172 Dilution Volume 308 oz 9 1 liters 2 4 gallons 1 512oz 0 00 15 15 liters 0 00 4 0 gallons 1 oz 0 05L 0 01G Unit default is fluid ounces Can...

Page 7: ...ess STOP to scroll through more sections See SAVE EXIT on page 5 or 14 For TBS 1222 only proceed to A4 A5 and A6 to program the left side From A3 00 screen Press STOP to scroll to A4 00 A4 00 is perma...

Page 8: ...splay indicator to change water filter BREW AT TEMPERATURE DEFINITIONS DEFAULT BREW AT TEMP ON FACTORY DEFAULT FOR BREWER BREW at TEMP Batch will not start if tank temperature is below set point Displ...

Page 9: ...ing Range Increments Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve T...

Page 10: ...m for low supply or Flojet use E5 Brew valve flow rate 54oz 1 60L 0 42G 45 64oz 1 30 1 90Liter 0 34 0 52G 1oz 0 05L 0 013G Adjusts flow rate by brew valve E9 Dilute valve flow 86oz 2 55L 0 67G 38oz 11...

Page 11: ...low F5 Option BB Lock NO NO or YES Enables brew basket lock F8 Backup to USB Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F1...

Page 12: ...ow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate...

Page 13: ...ht side G15 B Rt Brews R G20 G55 component use cycles and volumes handled Available in ADVANCED counter only G5 G20 A Fill Cycles LT Hot water tank refill cycles Count Cycles of hot water tank refill...

Page 14: ...een From EXIT screen Press button 1 to toggle to the SAVE screen From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT to OPERA...

Page 15: ...cratch surface Weekly 1 Use a commercial tea dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray clea...

Page 16: ...supply inlet of the beverage equipment as possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in...

Page 17: ...cified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the counter or tabl...

Page 18: ...or the latest versions of all information Page 18 User Guide Operator instructions P209Re0August 2021 Parts Diagrams REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00583 00 TBS 122...

Page 19: ...00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 26 1 1001 00455 00 TOP COVER MBS TBS 1200 LARGE 2...

Page 20: ...co com for the latest versions of all information Page 20 User Guide Operator instructions P209Re0August 2021 REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00584 00 TBS 1222 Dual...

Page 21: ...00 TUBE DRAIN 5 8 OD X 3 8 ID X 10 LG 22 1 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 23 1 1025 00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00...

Page 22: ...S 2121 7 2 1024 00062 00 GROMMET SHORT SILICONE LEVEL AND TEMP PROBE 8 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 9 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 10 1 1023 00362 00 FITTIN...

Page 23: ...interchangeable with 1057 00076 00 5 1 1024 00063 00 O RING 3 15 16 x 3 32 CS DASH 154 BUNA N DURO A50 NS 4 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL NS 4 1084 00006 00 NUT 8 32 18 8 HEX M...

Page 24: ...00179 00 NUT BREW BASKET ORIFICE HOLDER 5 1 1023 00191 00 PLUG BB HANDLE GREEN NS 1 B020000G2BK Complete SQUARE Brew basket TBS 1221 t For SINGLE brewer only NS 1 B013000G2BK Complete ROUND Brew baske...

Page 25: ...e latest versions of all information Page 25 User Guide Operator instructions P209Re0August 2021 Wiring Diagram SSR T1221US 1A117 PM001 FOR SKU T1221US 1A117 PM001 T122DUS 1A117 PN00 T1221IN 1B130 PN0...

Page 26: ...Go to fetco com for the latest versions of all information Page 26 User Guide Operator instructions P209Re0August 2021 SSR FOR SKU T1221CE 1B130 PN005 CE T122DCE 1B130 PN005l CE...

Page 27: ...de 15 T61 UX120 12 Barcode 107546316 03754 Inches Lx W x H 11 25 x 8 50 x 8 50 Centimeters 28 6 x 21 6 x 21 6 Weight 14 6 lbs 6 6 kg Per Pallet 102 cases Layout 6 layers of 17 cases Weight 1 525 lbs 6...

Reviews: