Starting The Brew  

 

1. Turn the power switch “ON”.   

2. Prepare a brew basket with the correct size

 

filter and appropriate amount of tea. 

3. Slide the brew basket completely into the

 

rails. 

4. Place a clean, empty, dispenser

 

under the brew basket. 

5. Select a batch & hold the corresponding BREW button in

 

for 1 second to start  

6. -STOP button will illuminate,  Brew Selector button will illuminate 

    -Countdown time will display.  Default time setting is 6:45(iced tea) 

   -Selected BREW button will slowly pulsate to indicate brew is in progress.  

    -All other BREW buttons for that brew head will be unlit. 

7.Dilute DELAY cycle will activate at 3:45 

8. Dilute will activate at 3:30.   

 

Upon time out, brewer will return to “READY” for next batch 

STOP

 

button will extinguish and the BREW button will

 

illuminate on completion 

For safety- do not remove brew basket until drip-out is complete.

 

 

 

Enter Programming 

There are 7 menu groups-A-F plus EXIT (G).   

See the following pages for the batch parameter definitions and all settings for the brewer

 

 

 

 

 

 

 

 

TO ENTER PROGRAMMING 

1-Turn brewer “OFF” from power switch 

2-Turn power switch to “ON”

 

 

 

…Screen will initialize  and then 

 display digital process notifications   

 

3-After Initialization- “STOP” Lamp turns on 

4-Quickly press  “STOP” button (no need to hold)

 

 

 

 

 

 

 

 

 

 

 

      

 When brewer is In PROGRAMMING MODE 

      -the screen will display:

 

       

                         

|BATCH PRG| 

|A   

(or B-F)

   | 

-

Illuminated LED indicates active keypad positions 

 

See the following pages for batch parameter definitions 

and all settings for the brewer 

 

Enter Programming  to Make Changes 

 Section B –“General Settings” to change tank temperature shown below 

 

 

 

 

 

Enter Programming-Press 

STOP button until the 

General Settings (“B”)  

screen appears 

From the “B” screen 

Press button 

1

 to toggle 

to the Tank Temperature 

Screen (default is 200°) 

From Tank Temp screen 

Toggle buttons 

2

 & 

3

 to 

select the desired 

temperature 

From Tank Temp screen 

Press button 

1

 to toggle 

to the next selection in 

General Settings or SAVE 

To SAVE and EXIT 

Press the 

STOP 

button to 

the “H” screen.  Proceed  

to screen two below   

 

 

 

See the progammin menu layout table on the next page to locate the disired control setings to adjust. 

Batch size and menu brewing parameters are in section “A”.   

The most common settings for tank temperature satpoint , units of measure are in section “B”. 

 

 

 

Tank Temperature 

B1 

200°F+- 

 

 

 

 

 

 

 

 

 

STOP 

 

 

STOP 

Tank Temperature 

B1          171° to 207° 

 

 

 

 

 

 

 

 

 

STOP 

 

 

Brew at Temp 

B2 

YES- 

 

 

 

 

 

 

 

STOP 

 

 

EXIT 

NO  + 

 

 

 

 

STOP

 

Brewing 

6:45

 

FETCO 

Ready to Brew 

STOP BUTTON

 

 

 

ON/OFF switch 

is located on 

lower right on 

back of brewer 

 

STOP

 

 

TBS-1221 

Ver.

 

2.0.210317 

STOP 

 

   Batch Program 

   A

 

 

STOP 

 

 

 

STOP 

 

 

General Settings 

     B 

 

 

 

 

 

 

 

Summary of Contents for TEAVARIS PLUS TBS-1221

Page 1: ...d Tea Brewer FETCO TEAVARIS PLUS Commercial Beverage Equipment TBS 1221 Single Dilution Teavaris Plus TBS 1222 Dual Dilution Teavaris Plus Shown with ITD dispensers not included CONTACT INFORMATION FE...

Page 2: ...es Electrical Specifications for single domestic 120 volt cord and plug SKU Dilution Electrical Connection Heater Configuration Voltage KW Amp Draw Est 3gal Batches Hour T1221US 1A117 PM001 Domestic S...

Page 3: ...n a receiving dispenser for the left or right side brew orientation TBS 1221 Single dilution has a square brew basket and is only positioned in the center for three recipes A1 A2 and A3 Two position b...

Page 4: ...ze and then display digital process notifications 3 After Initialization STOP Lamp turns on 4 Quickly press STOP button no need to hold When brewer is In PROGRAMMING MODE the screen will display BATCH...

Page 5: ...kup to USB G5 Choose Counter A17 Dilute Mode B6 Units of Volume D13 LED Brightness F9 Restore from USB G10 Brewer Volume LT A17 Dilute Delay B7 Customers Name F10 Restore Defaults G11 Brewer Volume R...

Page 6: ...after brew to begin dilution Often used to add sweetener A172 Dilution Volume 308 oz 9 1 liters 2 4 gallons 1 512oz 0 00 15 15 liters 0 00 4 0 gallons 1 oz 0 05L 0 01G Unit default is fluid ounces Can...

Page 7: ...ess STOP to scroll through more sections See SAVE EXIT on page 5 or 14 For TBS 1222 only proceed to A4 A5 and A6 to program the left side From A3 00 screen Press STOP to scroll to A4 00 A4 00 is perma...

Page 8: ...splay indicator to change water filter BREW AT TEMPERATURE DEFINITIONS DEFAULT BREW AT TEMP ON FACTORY DEFAULT FOR BREWER BREW at TEMP Batch will not start if tank temperature is below set point Displ...

Page 9: ...ing Range Increments Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve T...

Page 10: ...m for low supply or Flojet use E5 Brew valve flow rate 54oz 1 60L 0 42G 45 64oz 1 30 1 90Liter 0 34 0 52G 1oz 0 05L 0 013G Adjusts flow rate by brew valve E9 Dilute valve flow 86oz 2 55L 0 67G 38oz 11...

Page 11: ...low F5 Option BB Lock NO NO or YES Enables brew basket lock F8 Backup to USB Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F1...

Page 12: ...ow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate...

Page 13: ...ht side G15 B Rt Brews R G20 G55 component use cycles and volumes handled Available in ADVANCED counter only G5 G20 A Fill Cycles LT Hot water tank refill cycles Count Cycles of hot water tank refill...

Page 14: ...een From EXIT screen Press button 1 to toggle to the SAVE screen From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT to OPERA...

Page 15: ...cratch surface Weekly 1 Use a commercial tea dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray clea...

Page 16: ...supply inlet of the beverage equipment as possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in...

Page 17: ...cified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the counter or tabl...

Page 18: ...or the latest versions of all information Page 18 User Guide Operator instructions P209Re0August 2021 Parts Diagrams REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00583 00 TBS 122...

Page 19: ...00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 26 1 1001 00455 00 TOP COVER MBS TBS 1200 LARGE 2...

Page 20: ...co com for the latest versions of all information Page 20 User Guide Operator instructions P209Re0August 2021 REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00584 00 TBS 1222 Dual...

Page 21: ...00 TUBE DRAIN 5 8 OD X 3 8 ID X 10 LG 22 1 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 23 1 1025 00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00...

Page 22: ...S 2121 7 2 1024 00062 00 GROMMET SHORT SILICONE LEVEL AND TEMP PROBE 8 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 9 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 10 1 1023 00362 00 FITTIN...

Page 23: ...interchangeable with 1057 00076 00 5 1 1024 00063 00 O RING 3 15 16 x 3 32 CS DASH 154 BUNA N DURO A50 NS 4 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL NS 4 1084 00006 00 NUT 8 32 18 8 HEX M...

Page 24: ...00179 00 NUT BREW BASKET ORIFICE HOLDER 5 1 1023 00191 00 PLUG BB HANDLE GREEN NS 1 B020000G2BK Complete SQUARE Brew basket TBS 1221 t For SINGLE brewer only NS 1 B013000G2BK Complete ROUND Brew baske...

Page 25: ...e latest versions of all information Page 25 User Guide Operator instructions P209Re0August 2021 Wiring Diagram SSR T1221US 1A117 PM001 FOR SKU T1221US 1A117 PM001 T122DUS 1A117 PN00 T1221IN 1B130 PN0...

Page 26: ...Go to fetco com for the latest versions of all information Page 26 User Guide Operator instructions P209Re0August 2021 SSR FOR SKU T1221CE 1B130 PN005 CE T122DCE 1B130 PN005l CE...

Page 27: ...de 15 T61 UX120 12 Barcode 107546316 03754 Inches Lx W x H 11 25 x 8 50 x 8 50 Centimeters 28 6 x 21 6 x 21 6 Weight 14 6 lbs 6 6 kg Per Pallet 102 cases Layout 6 layers of 17 cases Weight 1 525 lbs 6...

Reviews: