User Guide & Operator instructions
P213
e0
NOVEMBER 2021
C Service Inputs
Brewer Sensors and Keypad
POSITION Program Items
Factory set Default
Programming Range Increments
Notes
C1
LLC Probe
continuity
Direct read
Tank water
resistance in TDS
≈850
- LOW
≈1600
-HIGH
Nominal values
C2
Brew Basket
Sensor
L-YES R-YES
YES or NO
C4
Tank
Temperature
Direct read
Hot water tank
temperature
Actual values
C5
USB Drive
NO
(not in use)
C6
Keyboard Test
Calibrate
Checks buttons
under membrane
cover
YES/NO
Follow directions on the
touch screen
D Service Outputs
Test Valves and Heaters; Set screen brightness
POSITION
Program Items
Factory set Default Programming Range
Increments
Notes
D1
Heater SSR Test
Press button 2 to
test (button 1 stops
test)
Activates heater
Default is 10 sec..
/-
OFF or ON
Energizes Heater(s)
WARNING!
Service use only.
D2
Fill Valve Test
Press button 2 to
test (button 1 stops
test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Press To Test
D3
LT (left)
Brew Valve Test
(Press to test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Runs valve to verify flow.
NOTE: Have container
under brew basket.
D4
RT (right)
Brew Valve Test
(Press to test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Runs valve to verify flow.
NOTE: Have container
under brew basket.
D5
LT (left)
Bypass Valve Test (Press to test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Runs valve to verify flow.
NOTE: Have container
under brew basket.
D6
RT (right)
Brew Valve Test
(Press to test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Runs valve to verify flow.
NOTE: Have container
under brew basket.
D7
LT (left)
Brew Basket Lock
Test
(Press to test)
Activates Brew
Basket Lock
/-
OFF or ON
Press To Test
D8
RT (right)
Brew Basket Lock
Test
(Press to test)
Activates Brew
Basket Lock
/-
OFF or ON
Press To Test
Single series displays right side only Left Valve display is only for twin side brewer.
D12
LCD Brightness
Brightness=90%
20-100%
5%
Adjust LCD screen
brightness only-Not for
LEDs under buttons
D13
LED Brightness
Brightness=60%
20-100%
5%
Adjust LED button
brightness only-Not for
the screen display LCD