F Error Codes
DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact factory or specialized personnel for error codes
Code Description
Possible Cause
Corrective Action
001
Software error-error on start up or
corrupted software
Improper start-up or
shutdown
Restart , if still fault: reload software
002 Internal flash corrupted
internal data memory malfunction
Error found in
cyclic
redundancy check
CRC
Restart , if still fault: reload software
If not corrected :replace board
050 Short-circuit in temperature probe
Probe failure.
Replace probe.
051 Open temperature probe.
Bad probe connection, or
probe failure.
Check all connections. Replace probe if
necessary.
100
Initial Fill Error.
Initial fill time took longer than
expected after powering up.
Water supply flow rate is too
low.
Watch for short potting during brew cycle.
Investigate cause of low flow rate.
(Clogged water filter...)
101
Error on refill-.
Tank did not refill within expected
time. Water flow too slow from main.
Water supply flow rate is too
low. (External to brewer.)
Watch for short potting during brew cycle.
Investigate cause of low flow rate.
(Clogged water filter…)
200 Heating flatline-Tank is boiling
Heater is on, temperature is
not rising/dropping
High elevation correction. Bad heaters or
temperature probe or position
201 Heater open, high limit thermostat,
or Solid State Relay (SSR) fault
Failure of heating element,
SSR, high limit or low voltage
Check that ohms range of heater are
between 10-
80Ω; replace if not.
Check for continuity, and if open replace
high limit devices. Check if permanently
closed and replace SSRs,if necessary.
202 Heater Shorted or Stuck SSR
Heater is off and equipment is
heating. SSR is stuck “ON”
Check that ohms range of heater are
between 10-
80Ω; replace if not. Check if
permanently closed SSR may be stuck in
ON mode-replace SSR. Test output on
solid state relay
255 Keyboard [HID] error
Usually from longer than 10
se contact. Or faulty
reassembly after service
Restart , if still fault: reload software. If
mechanical: replace module
NO
BSKT
Insert Brew Basket
Brew basket must be in place
This is a
SAFETY FEATURE
Insert brew basket into brewer rails to
enable brewer